CHAPTER4<br />

Review Procedures<br />

The reviewer should confirm that the design bases describe the requirements for<br />

the tank and that the detailed design is consistent with the design bases and<br />

acceptance criteria for the tank.<br />

Evaluation Findings<br />

This section of the SAR should contain sufficient information to support the<br />

following types of conclusions, which will appear in the staffs safety evaluation<br />

report:<br />

* The tank system can withstand all anticipated mechanical and hydraulic<br />

forces and stresses to prevent loss of integrity which could lead to a loss of<br />

coolant or other malfunction that could interfere with safe reactor<br />

operation or shutdown.<br />

* The penetrations and attachments to the tank are designed to ensure safe<br />

reactor operation. Safety and design considerations of any penetrations<br />

below the water level include analyses of potential malfunction and loss of<br />

coolant. The applicant discusses credible loss-of-coolant scenarios in<br />

Chapter 13, "Accident Analyses."<br />

* The construction materials, treatment, and methods of attaching<br />

penetrations and components are designed to prevent chemical interactions<br />

among the tank, the coolant, and other components.<br />

* The outer surfaces of the tank are designed and treated to avoid corrosion<br />

in locations that are inaccessible for the life of the tank. Tank surfaces will<br />

be inspected in accessible locations.<br />

* The applicant has considered the possibility that primary coolant may leak<br />

into unrestricted areas, including ground water, and has included<br />

precautions to avoid the uncontrolled release of radioactive material.<br />

* The design considerations include the shape and dimensions of the tank to<br />

ensure sufficient radiation shielding to protect personnel and components.<br />

Exposures have been analyzed, and acceptable shielding factors are<br />

included in the tank design.<br />

* The applicant has justified appropriate limiting conditions for operation and<br />

surveillance requirements for the tank and included them in the technical<br />

specifications.<br />

<strong>NUREG</strong>-<strong>1537</strong>,PART2<br />

4-16<br />

REv 0,2/96<br />

<strong>NUREG</strong>-<strong>1537</strong>,PART2 4-16 REV 0, 2196