REACTOR COOLANT SYSoM<br />

discussed in Chapter I 1, and potential exposures and releases to the<br />

unrestricted environment shall not exceed the requirements of 10 CFR <strong>Part</strong><br />

20 and should be consistent with the facility ALARA program.<br />

Location, shielding, and radiation monitoring of the water cleanup system<br />

for routine operations and potential accidental events should be such that<br />

the occupational staff and the public are protected from radiation<br />

exposures exceeding the requirements of 10 CFR <strong>Part</strong> 20 and acceptable<br />

radiological consequence dose limits for accidents.<br />

* Location and functional design of the components of the water cleanup<br />

system should ensure the following:<br />

- Malfunctions or leaks in the system do not cause uncontrolled loss<br />

or release of primary coolant. :<br />

- Personnel exposure and release of radioactivity do not exceed the<br />

requirements of 10 CFR <strong>Part</strong> 20 and are consistent with the facility<br />

ALARA program :<br />

- Safe reactor shutdown is not prevented.<br />

* The applicant should identify operational limits, design parameters, and<br />

surveillances to be included in the technical specifications.<br />

Revew Procedures<br />

The reviewer should compare the design bases for the primary coolant water<br />

quality with the design bases by which the primary coolant cleanup system will<br />

achieve the requirements. The comparison should include performance<br />

specifications, schematic diagrams, and discussion of the functional charactenstics<br />

of the cleanup system. The reviewer should evaluate (1) design features to ensure<br />

that leaks or other malfunctions would not cause inadvertent damage to the reactor<br />

or exposure of personnel and (2) the plan'for control and disposal of radioactive<br />

filters and demineralizer resins. :.<br />

Evaluamon Findings .-<br />

This section of the SAR should contain sufficient information to support the<br />

following types of conclusions, which will be included in the staffs safety<br />

evaluation report:<br />

* The design bases and functional descriptions of the primary water cleanup<br />

system give reasonable assurance that the required water quality can be<br />

REV. 0, 296 S-Il STANDARD REVIEW PLAN<br />

REV.0,2/96 : 5-1 1 STANDARD REVEL% PLAN