CHAPTER 3<br />

Evaluation Findings<br />

This section of the SAR should contain sufficient information to support the<br />

following type of conclusion, which will be included in the staffs safety evaluation<br />

report:<br />

The design to protect against meteorological damage provides reasonable<br />

assurance that the facility structures, systems, and components will perform<br />

the safety functions discussed in the SAR, including the capability to<br />

maintain safe reactor operation, to effect and maintain safe reactor<br />

shutdown conditions, and to protect the health and safety of the public<br />

from radioactive materials and radiation exposure.<br />

3.3 Water Damage<br />

Areas of Review<br />

Areas of review should include the design and design bases for all structures,<br />

systems, and components that could be affected by predicted hydrological<br />

conditions at the site. This should include (1) the impact on structures resulting<br />

from the force or submergence of flooding, (2) the impact on systems resulting<br />

from instrumentation and control electrical or mechanical malfunction due to<br />

water, and (3) the impact on equipment, such as fans, motors, and valves, resulting<br />

from degradation of the electromechanical function due to water.<br />

Acceptance Criteria<br />

The acceptance criteria for the information on water damage include the following:<br />

* The design criteria and designs should provide reasonable assurance that<br />

structures, systems, and components would continue to perform required<br />

safety functions under water damage conditions.<br />

* For the design the applicant should use local building codes, as applicable,<br />

to help ensure that water damage to structures, systems, and components<br />

at the facility site would not cause unsafe reactor operation, would not<br />

prevent safe reactor shutdown, and would not cause or allow uncontrolled<br />

release of radioactive material.<br />

Review Procedures<br />

The reviewer should examine the site description to ensure that all safety-related<br />

structures, systems, and components with the potential for hydrological (water)<br />

damage are considered in this SAR section. The review should include<br />

<strong>NUREG</strong>- <strong>1537</strong>, PART 2 3-4 REV. 0,2/96<br />

<strong>NUREG</strong>- <strong>1537</strong>, PART 2 3-4 -REV. 0, 2196