1 Overview of the <strong>Process</strong> <strong>Unit</strong> <strong>73</strong> <strong>LF</strong><br />

Commissioning of the <strong>Process</strong> <strong>Unit</strong> <strong>73</strong> <strong>LF</strong> must be<br />

carried out only by specially trained personnel in<br />

accordance with this instruction manual and per<br />

applicable local and national codes.<br />

Prior to commissioning, a complete parameter setting<br />

procedure must be performed.<br />

Instrument Concept<br />

Since we have largely followed NAMUR recommendations<br />

and customer demands – especially<br />

concerning safety, reliability and functional variety<br />

– this instrument provides state of the art technology<br />

showing a new standard for process instruments.<br />

User Interface<br />

The display interface consists of a backlit high-resolution<br />

graphical display (240 x 64 pixels) and a<br />

keypad.<br />

Each key has only one function and is definitely<br />

assigned to a menu or an input function.<br />

In measuring mode the graphical display allows<br />

simultaneous readout of the currently measured<br />

value via large numerals (25 mm) and of two further<br />

values on secondary displays, as well as display<br />

of status messages (to NAMUR) such as<br />

warning (maintenance required) and failure, and<br />

limit messages.<br />

Depending on your application, the displays can<br />

be assigned to different variables and output values:<br />

conductivity, resistivity, concentration, measured<br />

and manually entered temperature, time,<br />

date, output current values 1 and 2, input current<br />

in %, manipulated variable (controller output).<br />

Operator guidance is supported by a 7-line plaintext<br />

display with information texts. During operation,<br />

the currently measured value and active status<br />

messages remain visible.<br />

The keypad includes the keys (measurement),<br />

(calibration), (maintenance),<br />

(parameter setting), (diagnostics), a<br />

cursor pad for selecting menu items or entering<br />

alphanumeric characters and for confirming<br />

your entry.<br />

Overview 1–1