Tools Menu<br />
I/O Config<br />
The following table illustrates how the opto-isolators are used, with examples using opto-isolators 4 to 10:<br />
MSB Optos in between Path Type Optos in between LSB Path<br />
Opto 4<br />
(binary 4)<br />
Opto 5<br />
(binary 2)<br />
Opto 6<br />
(unary bit)<br />
Opto 7<br />
(binary 8)<br />
Opto 8<br />
(binary 4)<br />
Opto 9<br />
(binary 2)<br />
Opto 10<br />
(unary bit)<br />
0 0 1 1 = Main 0 0 1 0 MAI3<br />
0 1 0 2 = Aux 1 1 1 1 AU16<br />
0 1 1 3 = Ext 0 1 1 0 EXT7<br />
1 0 0 4 = Group 0 0 1 1 GRP4<br />
1 0 1 5 = Cue 0 0 0 0 CUE1<br />
SLS SELECT VALID<br />
This is used to execute routing of the path to the Studio Loudspeakers, as selected with SLS SELECT MSB and SLS<br />
SELECT LSB.<br />
HEADPHONE SELECT MSB and HEADPHONE SELECT LSB<br />
These are used to specify a range of seven opto-isolators that represent a source for the Headphones in binary<br />
form. The opto-isolators should not be used for anything else. The LSB opto-isolator number must be after the<br />
MSB opto-isolator number.<br />
The usage of the seven opto-isolators is identical to the format used for the Studio Loudspeakers.<br />
HEADPHONE SELECT VALID<br />
This is used to execute routing of the path to the Headphones, as selected with HEADPHONE SELECT MSB and<br />
HEADPHONE SELECT LSB.<br />
SNAPSHOT SELECT MSB and SNAPSHOT SELECT LSB<br />
These are used to specify a range of opto-isolators that represent a Snapshot number in binary form. The<br />
opto-isolators should not be used for anything else. The LSB opto-isolator number must be after the MSB<br />
opto-isolator number (see example below).<br />
The number of the Snapshot is as it is numbered in the current Snapshot file (see Filing, page :, and Snapshot,<br />
page :).<br />
The MSB (most significant bit) is the highest digit in the binary number and the LSB (least significant bit) is the<br />
unary digit (i.e. the 'ones' column of the number). Each opto-isolator represents 1 when it is closed or 0 when it is<br />
open.<br />
The following table illustrates an example using four opto-isolators (13 to 16) for snapshot numbers:<br />
MSB Optos in between LSB Snapshot<br />
Opto 13<br />
(binary 8)<br />
Opto 14<br />
(binary 4)<br />
Opto 15<br />
(binary 2)<br />
Opto 16<br />
(unary bit)<br />
Number<br />
1 1 0 1 13 (8+4+1)<br />
0 1 0 0 4<br />
SNAPSHOT SELECT VALID<br />
When the specified opto-isolator closes then the snapshot will be loaded, according to the number identified by<br />
the opto-isolators in the SNAPSHOT SELECT MSB to SNAPSHOT SELECT LSB range. If relays are assigned to<br />
show the selected Snapshot and if it is valid then they will close.<br />
To save changes to the I/O Configuration click the Save & Load button.<br />
If the I/O Configuration is not linked to the current Desk Setup then a prompt will be displayed asking if it should<br />
be associated with the current Desk Setup.<br />
Issue 4 Page 24:26