Potentiel d’économies d’énergie par les services énergétiques – Application au cycle de vie<br />

des équipements de conversion de l’énergie<br />

Annexe 2 : Exemple de contrat de performance<br />

énergétique sous mécanisme « Guaranteed Savings » –<br />

Exploitation et maintenance d’un automate de gestion<br />

énergétique<br />

Galva Plus is specialized in the hot galvanization of steel parts (barriers...). The main<br />

equipment that needs electricity is an induction furnace used to maintain the Zinc in fusion<br />

(450 °C). The latter is operating 24 h/24 and is on/off controlled: when the temperature of the<br />

Zinc bath passes below the set point, the furnace is commanded to heat with full power<br />

independently of the difference to this reference value. This kind of control thus does not<br />

allow to manage the amplitude of the power demand and can generate important peaks. On<br />

the other hand, when the furnace is off, the power demand of the site is low. In the framework<br />

of an approach initiated by EDF, LM Control intervenes on site in order to optimize power<br />

calls.<br />

The invoicing of Electricity in France<br />

The invoicing of EDF is based on two criteria: on the one hand a subscribed power and on the<br />

other hand a price per kilowatt-hour consumed. The knowledge of consumption of the site<br />

allows to optimize tariffs by balancing the subscribed power and the possible overstepping.<br />

The subscribed power is then slightly lower than the total power absorbed. In spite of<br />

optimization, EDF is conscious that it is possible to more decrease the subscribed power and<br />

then to reduce the invoice of electricity. Indeed, EDF invoices its customers compared to their<br />

load diagram which is established by averaging the power called over ten minutes. By<br />

reducing the amplitude of power calls, it is possible to reduce the subscribed power and thus<br />

the invoice.<br />

The energy management system<br />

Before the energy management device is set up, each process could call power at the same<br />

time so that important peaks appeared on the load diagram. The client was then obliged to<br />

subscribe a electricity supply contract in relation to the amplitude of these peaks.<br />

This device allows to manage power calls. Indeed, when the power called passes over the set<br />

point, the device switch the supply of certain equipments off. Also, when the power called<br />

passes below the set point, the device switch the supply of certain equipments on. The on/off<br />

priority depends on the process and the customer choices. Finally, load management with this<br />

device is possible only for equipments with inertia and is then favorable for thermal uses<br />

(furnace, cold group, …).<br />

The specificity of the Galva Plus optimizer is that it manages only the furnace. LM Control<br />

implements a power set point into the optimizer and synchronizes its clock with the EDF<br />

network. In a 10 minutes interval, the optimizer calculates in real time the average power and<br />

avoids exceeding the power set point by ordering the stop of the heat sequence even if the<br />

Zinc bath did not reach the reference temperature. At the beginning of the next 10 minutes<br />

interval, the optimizer restores the signal to the furnace and proceeds in the same way until<br />

the reference temperature is reached.<br />