Potentiel d’économies d’énergie par les services énergétiques – Application au cycle de vie<br />

des équipements de conversion de l’énergie<br />

The FIDELIO approach<br />

In the optics of the opening of the markets of energy, EDF initiated a policy called FIDELIO<br />

for customer loyalty building. EDF selected two ESCOs (LM Control and Energie System)<br />

specialized in energy management. This approach includes four separated phases in order not<br />

to invoice all the service if the project is not feasible (phase 1 report) or if the customer<br />

decides not to apply the recommended solutions (phase 2 report):<br />

• Feasibility study (1000 €): EDF determines the equipments that are the principal cause<br />

of power calls and makes a report favorable or not to the prolongation of the approach.<br />

• Audit (3500 €): The ESCO measures the consumption of considered equipments<br />

during the ten days period which is as representative of the real consumption of the<br />

site as possible. The ESCO also takes into account the will of the customer<br />

(investment, mark of the device, payback time etc...) as well as production parameters.<br />

A report including a technical solution (type of optimizer) with engagement of results<br />

on the generated savings is finally proposed.<br />

• Works management (3000 €): The installation can be supervised either by the<br />

customer or by the ESCO. The device and its installation (25000 €) are not included in<br />

the price.<br />

• Follow-up (one year, price to be negotiated with the ESCO): The ESCO intervenes in<br />

order to adjust the optimizer. Indeed, the measurement campaign is not completely<br />

representative, it is sometimes necessary to intervene.<br />

By this approach, EDF wants to decrease of a minimum of 10 % the bill of its customers with<br />

a return on investment lower than two years.<br />

Interest of such an approach<br />

The main use of this optimizer is to reduce the electricity invoice by smoothing the load<br />

diagram. However, in the French current context of low electricity price, this process<br />

represents an important behavioral change because it leads to define a maximum parts flow to<br />

galvanize and thus limits power calls.<br />

The interest for EDF is double: The management of the electricity production is easier when<br />

the overall load diagram is flat. However, due to the opening of energy markets, the<br />

comparison of supplier tenders became possible and thus could not be in favor of EDF<br />

without optimization. This process is thus a way to develop the loyalty of the customer by<br />

proposing solutions to reduce the electricity bill without any supplier switching.<br />