Section I Detailed functions of <strong>ExpressCluster</strong><br />

Error messages of the compatible commands<br />

Error messages of the compatible commands<br />

Message Description Solution<br />

armbcast succeeded. armbcast succeeded. -<br />

armbcast has received an invalid armbcast received an invalid Specify the valid input<br />

parameter.<br />

parameter.<br />

parameter.<br />

armbcast failed in the internal armbcast T failed in the internal Check if the memory is sufficient<br />

processes (1%03d). The error code<br />

is 0x%x.<br />

processing.<br />

and/or OS is stable.<br />

Cannot execute armbcast. armbcast cannot be executed. armbcast cannot be used when<br />

the arms_event of the start<br />

script is in the recover status.<br />

This is because the server is<br />

recovering the cluster.<br />

armcall succeeded. command<br />

name=%.16s.<br />

armcall succeeded. -<br />

armcall has received an invalid armcall received an invalid<br />

Specify an valid input<br />

parameter.<br />

parameter.<br />

parameter.<br />

armcall failed to lock the file. armcall failed to acquire the<br />

Check if the memory is sufficient<br />

privilege to write lock <strong>for</strong> exclusive<br />

access control.<br />

and/or OS is stable.<br />

armcall received a console close The server was shut down because -<br />

signal. The server will be shut down. the armcall console window was<br />

closed by a user’s request.<br />

armcall failed in the internal armcall failed in the internal<br />

Check if the memory is sufficient<br />

processes ("%03d"). The error code<br />

is 0x%x.<br />

processing.<br />

and/or OS is stable.<br />

armcall failed to execute the Execution of exec-name specified in Check if the valid values are<br />

command line. The error code is the command line of armcall failed. specified <strong>for</strong> the path name, file<br />

0x%x.<br />

name and parameter-n in the<br />

command lines.<br />

armdown succeeded. option=%s. armdown succeeded. -<br />

armdown has received an invalid armdown received an invalid Specify an valid input<br />

parameter. option=%s.<br />

parameter.<br />

parameter.<br />

armdown shuts down the server. armdown started a server<br />

-<br />

option=%s.<br />

shutdown.<br />

armdown cannot execute specified armdown cannot be executed. The server may have failed.<br />

action. option=%s<br />

Check it.<br />

armdown failed in the internal armdown failed in the internal Check if the memory is sufficient<br />

processes (%03d). The error code<br />

is 0x%x.option=%s<br />

processing.<br />

and/or OS is stable.<br />

armem succeeded.mode=%s. armem succeeded. -<br />

armem has received an invalid<br />

parameter.<br />

armdown failed in the internal<br />

processes (%04d). The error code<br />

is 0x%x.option=%s<br />

arm<strong>for</strong>ver succeeded.<br />

option=%s group-name=%s<br />

arm<strong>for</strong>ver has received an invalid<br />

parameter.<br />

option=%s group-name=%s<br />

Cannot execute armfover .<br />

option=%s group-name=%s<br />

armem received an invalid<br />

Specify a valid input parameter.<br />

parameter.<br />

armem failed in the internal process. Check if the memory is sufficient<br />

and/or OS is stable.<br />

arm<strong>for</strong>ver succeeded. -<br />

arm<strong>for</strong>ver received an invalid<br />

parameter.<br />

Specify a valid input parameter.<br />

arm<strong>for</strong>ver cannot be executed. Check if the failover group is<br />

being stopped or is already<br />

stopped.<br />

377