Section III Maintenance in<strong>for</strong>mation<br />

Media sense function becomes invalid<br />

Running the <strong>for</strong>cible mirror recovery from the WebManager only<br />

on one server<br />

In some cases, you cannot start one of the servers due to a hardware or OS failure, and the server<br />

that can be started may not have the latest data. If you want to start applications at least on the<br />

server that can be started, you can per<strong>for</strong>m the <strong>for</strong>cible mirror recovery on that server.<br />

However, remember that if you do this, the data on the server where you run this command<br />

becomes the latest data no matter which server actually has it. There<strong>for</strong>e, even if the other server<br />

becomes available later, you cannot handle the data in that server as the latest one. Make sure<br />

you understand the consequence be<strong>for</strong>e running the following command.<br />

Start the Mirror Disk Helper from the WebManager to start the <strong>for</strong>cible mirror recovery. Select<br />

the icon of the server, which you want to per<strong>for</strong>m the <strong>for</strong>cible mirror recovery. The icon will be<br />

changed as follows. Click Execute to per<strong>for</strong>m the <strong>for</strong>cible mirror recovery processing.<br />

When the <strong>for</strong>cible mirror recovery is successfully completed, you can activate the groups and use<br />

the mirror disks.<br />

Media sense function becomes invalid<br />

Media sense function is the OS function that detects disconnection of network cable. When<br />

disconnection is detected, TCP/IP receives a notification from the media sense function and<br />

renders the in<strong>for</strong>mation such as an IP address assigned to the disconnected network card<br />

unavailable while it is disconnected. <strong>ExpressCluster</strong> cannot be operated properly if the<br />

in<strong>for</strong>mation such as IP address becomes invalid during its operation, so the media sense function<br />

is rendered invalid when installing <strong>ExpressCluster</strong>.<br />