Chapter 13 Error messages<br />

IMAP4 monitor resource<br />

Module<br />

Type<br />

840<br />

Type<br />

imap4w Error 1<br />

imap4w Error 2<br />

imap4w Error 10<br />

imap4w Error 11<br />

imap4w Error 12<br />

imap4w Error 13<br />

imap4w Error 15<br />

Return<br />

Value<br />

Message Description Solution<br />

Initialization has<br />

failed[%1!s!].<br />

The configured value is<br />

not correct.<br />

A function error was<br />

detected.<br />

An error was detected in<br />

accessing the monitor<br />

target.<br />

An error was detected in<br />

user authentication.<br />

An application error was<br />

detected.<br />

A data error was<br />

detected.<br />

imap4w Error 40 No license is registered.<br />

imap4w Error 60<br />

Failed to obtain the<br />

configuration data.<br />

Initialization process has<br />

failed. It may be due to<br />

memory allocation<br />

failure.<br />

In<strong>for</strong>mation on the<br />

initialization may be<br />

displayed on %1.<br />

The configured value of<br />

the monitoring is not<br />

correct.<br />

A function error<br />

occurred.<br />

The access to the<br />

monitor application<br />

failed.<br />

The access to the<br />

monitor application<br />

failed.<br />

A monitor application<br />

error was detected.<br />

A value of the response<br />

data has an error.<br />

The license has not<br />

been registered.<br />

The configured value<br />

could not be obtained.<br />

OS itself may have<br />

errors. Restart the<br />

server or take other<br />

actions<br />

Check the configured<br />

value on the Builder<br />

since it may not be<br />

correct.<br />

Monitor applications or<br />

OS may have errors.<br />

Check the status of the<br />

system.<br />

Check configured values<br />

on the Builder (such as<br />

an IP address). If there<br />

is no error, check if the<br />

monitor application has<br />

errors.<br />

Check configured values<br />

on the Builder (such as<br />

a user name or a<br />

password). If there is no<br />

error, check if the<br />

monitor application has<br />

errors.<br />

Refer to error messages<br />

<strong>for</strong> monitor applications<br />

described separately to<br />

fix errors.<br />

Refer to error messages<br />

<strong>for</strong> monitor applications<br />

described separately to<br />

fix errors.<br />

Register the license.<br />

OS may have errors.<br />

Restart the server or<br />

take other actions.<br />

<strong>ExpressCluster</strong> X <strong>2.0</strong> <strong>for</strong> <strong>Windows</strong> <strong>Reference</strong> <strong>Guide</strong>