Module<br />

Type<br />

Event<br />

Type<br />

Event<br />

ID<br />

rc Error 1059<br />

Section III Maintenance in<strong>for</strong>mation<br />

Messages Description Solution<br />

Server %1 is not in a<br />

condition to move<br />

group %2.<br />

cannot-move-group<br />

Messages reported by event log and alert<br />

Per<strong>for</strong>m server recovery if the<br />

target server is suspended<br />

(Isolated). If it is suspended<br />

(Network Partition Unsolved),<br />

recover network partition<br />

resources to normal status.<br />

Alert<br />

●<br />

Event log<br />

User log<br />

801<br />

Report Manager<br />

setting Alive<br />

Mail report<br />

rc In<strong>for</strong>mation<br />

Failing over the<br />

1060<br />

group %1.<br />

group-failover started - ● ● ●<br />

rc In<strong>for</strong>mation<br />

The group %1 has been<br />

1061<br />

failed over.<br />

group-failover ended - ● ● ●<br />

rc Error<br />

Failed to fail over the<br />

1062<br />

group %1.<br />

group-failover failed<br />

Troubleshoot according to the<br />

group resource message.<br />

● ● ● ●<br />

rc In<strong>for</strong>mation 1070 Restarting the group %1. group-restart started - ● ● ●<br />

rc In<strong>for</strong>mation<br />

The group %1 has been<br />

1071<br />

restarted.<br />

group-restart ended - ● ● ●<br />

rc Error<br />

Failed to restart the<br />

1072<br />

group %1.<br />

group-restart failed<br />

Troubleshoot according to the<br />

group resource message.<br />

● ● ● ●<br />

rc In<strong>for</strong>mation<br />

Restarting the<br />

1080<br />

resource %1.<br />

resource-restart started - ● ● ●<br />

rc In<strong>for</strong>mation<br />

The resource %1 has<br />

1081<br />

been restarted.<br />

resource-restart ended - ● ● ●<br />

rc Error<br />

Failed to restart the<br />

1082<br />

resource %1.<br />

resource-restart failed<br />

Troubleshoot according to the<br />

group resource message.<br />

● ● ● ●<br />

rc In<strong>for</strong>mation<br />

Shutting down the<br />

1090<br />

cluster.<br />

cluster shutdown - ● ● ●<br />

rc In<strong>for</strong>mation<br />

Shutting down the<br />

1091<br />

server.<br />

server shutdown -<br />

Server will automatically be<br />

● ● ●<br />

rc Error<br />

Group %1 is started on<br />

1092<br />

more than one server.<br />

group double start<br />

shut down. Check the cause<br />

<strong>for</strong> the group to be started in<br />

more than one server.<br />

It is considered as an error if<br />

● ● ● ● ●<br />

The system shutdown system shutdown by the system shuts down by<br />

rc Error 1093 was per<strong>for</strong>med by other other than cluster other than cluster service. ● ● ● ●<br />

than the cluster service.<br />

Shutdown count is<br />

service<br />

Follow the appropriate steps to<br />

shut down the system.<br />

rc Warning 1100<br />

reached the maximum<br />

number (%1). Final<br />

action of resource %2<br />

was ignored.<br />

shutdown count reached<br />

-<br />

the limit<br />

● ● ● ● ●<br />

rc In<strong>for</strong>mation<br />

Server %1 is returned to<br />

1110 server returned<br />

the cluster.<br />

- ● ● ●<br />

rc In<strong>for</strong>mation<br />

Server %1 is isolated<br />

1111<br />

from the cluster.<br />

server isolated - ● ● ●<br />

rc In<strong>for</strong>mation<br />

Server %1 started to<br />

1112<br />

return to the cluster.<br />

server return start - ● ● ●<br />

rc Error<br />

Server %1 failed to<br />

1113<br />

return to the cluster.<br />

Server %1 will notify the<br />

server return fail<br />

The system may not be able to<br />

operate properly.<br />

● ● ● ●<br />

rc In<strong>for</strong>mation 1120<br />

automatic running<br />

control software of<br />

shutdown start.<br />

The automatic running<br />

shutdown notification<br />

start<br />

- ● ● ●<br />

control software returned<br />

The automatic operating<br />

rc Error 1121 an error to the shutdown shutdown notification fail settings may be incorrect. ● ● ● ●<br />

start notification in<br />

server %1.<br />

Check the settings.