Chapter 13 Error messages<br />

Module<br />

Type<br />

834<br />

Type<br />

diskw Error 10<br />

diskw Error 70<br />

diskw Error 71<br />

diskw Error 72<br />

diskw Error 73<br />

diskw Error 74<br />

Return<br />

Value<br />

Message Description Solution<br />

Failed to allocate<br />

memory.<br />

Timeout has occurred<br />

when initializing internal<br />

resources.<br />

Timeout has occurred<br />

when opening the file.<br />

Timeout has occurred<br />

when writing in the file.<br />

Timeout has occurred<br />

when synchronizing the<br />

disk of the file.<br />

Timeout has occurred<br />

when closing the file.<br />

Failed to allocate<br />

memory.<br />

Timeout has occurred<br />

when initializing internal<br />

resources.<br />

Timeout has occurred<br />

when opening the file.<br />

Timeout has occurred<br />

when writing in the file.<br />

Timeout has occurred<br />

when synchronizing the<br />

disk of the file.<br />

Timeout has occurred<br />

when closing the file.<br />

diskw Error 90 Internal error occurred. Internal error occurred.<br />

resources may not be<br />

sufficient. Check them.<br />

Memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check if the monitoring<br />

target disk is connected<br />

properly, the disk is<br />

powered on, or no other<br />

errors are occurred on<br />

the disk. The system<br />

may be under high load,<br />

or memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check if the monitoring<br />

target disk is connected<br />

properly, the disk is<br />

powered on, or no other<br />

errors are occurred on<br />

the disk. The system<br />

may be under high load,<br />

or memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check if the monitoring<br />

target disk is connected<br />

properly, the disk is<br />

powered on, or no other<br />

errors are occurred on<br />

the disk. The system<br />

may be under high load,<br />

or memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check if the monitoring<br />

target disk is connected<br />

properly, the disk is<br />

powered on, or no other<br />

errors are occurred on<br />

the disk. The system<br />

may be under high load,<br />

or memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check if the monitoring<br />

target disk is connected<br />

properly, the disk is<br />

powered on, or no other<br />

errors are occurred on<br />

the disk. The system<br />

may be under high load,<br />

or memory or OS<br />

resources may not be<br />

<strong>ExpressCluster</strong> X <strong>2.0</strong> <strong>for</strong> <strong>Windows</strong> <strong>Reference</strong> <strong>Guide</strong>