Chapter 13 Error messages<br />

Module<br />

Type<br />

848<br />

Type<br />

psqlw Error 12<br />

psqlw Error 13<br />

psqlw Error 14<br />

psqlw Error 15<br />

Return<br />

Value<br />

Message Description Solution<br />

An error was detected in<br />

user authentication.<br />

An application error was<br />

detected.<br />

An error was detected in<br />

executing SQL<br />

statement [%1!s!].<br />

A data error was<br />

detected.<br />

psqlw Error 40 No license is registered.<br />

psqlw Error 60<br />

Failed to obtain the<br />

configuration data.<br />

The access to the<br />

database failed.<br />

The database error was<br />

detected.<br />

Executing SQL<br />

statement failed.<br />

The executed SQL<br />

statement is displayed<br />

on %1.<br />

A value on the table of<br />

database has an error.<br />

The license has not<br />

been registered.<br />

The configured value<br />

could not be obtained.<br />

Registry synchronization monitor resource<br />

Module<br />

Type<br />

Type<br />

regsyncw Error 50<br />

Return<br />

Value<br />

regsyncw Warning 101<br />

Message Description Solution<br />

Failed to save<br />

registry.<br />

Setting of registry<br />

keys is invalid.<br />

The process of storing to<br />

a file at detection of<br />

registry update failed.<br />

An invalid registry key is<br />

registered to the<br />

resource.<br />

Check configured values<br />

on the Builder (such as<br />

a user name or a<br />

password). If there is no<br />

error, check if the<br />

database has errors.<br />

Refer to error messages<br />

<strong>for</strong> database described<br />

separately to fix errors.<br />

Refer to error messages<br />

<strong>for</strong> database described<br />

separately to fix errors.<br />

Database may be<br />

corrupt. Stop the<br />

database operation and<br />

investigate it. This error<br />

may occur when more<br />

than one monitoring is<br />

per<strong>for</strong>med with the same<br />

monitor table name<br />

concurrently. Check if<br />

the values set in the<br />

multi-directional<br />

environment are<br />

appropriate.<br />

Register the license.<br />

OS may have errors.<br />

Restart the server or<br />

take other actions.<br />

Check if the process<br />

other than<br />

<strong>ExpressCluster</strong> opens<br />

the registry storage file.<br />

Memory or OS<br />

resources may not be<br />

sufficient. Check the<br />

status of the system.<br />

Check the value set on<br />

the Builder (Details on<br />

Resource Properties),<br />

and change to a correct<br />

registry key.<br />

<strong>ExpressCluster</strong> X <strong>2.0</strong> <strong>for</strong> <strong>Windows</strong> <strong>Reference</strong> <strong>Guide</strong>