Chapter 13 Error messages<br />

Module<br />

Type<br />

838<br />

Type<br />

hdtw Error 99<br />

Return<br />

Value<br />

Message Description Solution<br />

Other internal error has<br />

occurred. Check the<br />

system resource.<br />

Hybrid disk monitor resource<br />

Module<br />

Type<br />

Type<br />

Return<br />

Value<br />

hdw Error 2 Internal error.<br />

hdw Error 3 HDR %1 has old data.<br />

hdw Error 4<br />

hdw Error 5<br />

hdw Warning 101<br />

hdw Warning 102<br />

hdw Warning 103<br />

hdw Warning 104<br />

hdw Warning 105<br />

HTTP monitor resource<br />

Module<br />

Type<br />

Type<br />

httpw Error 1<br />

httpw Error 2<br />

Return<br />

Value<br />

Other internal error has<br />

occurred. Check the<br />

system resource.<br />

Message Description Solution<br />

A disk error is detected<br />

in HDR %1.<br />

The status of HDR %1<br />

is invalid.<br />

HDR %1 recovery is in<br />

progress.<br />

HDR %1 is not being<br />

mirrored.<br />

HDR %1 is activated on<br />

more than one server.<br />

The status of HDR %1<br />

is unknown.<br />

Whether HDR %1 data<br />

is old/new is not<br />

determined.<br />

An internal error has<br />

occurred.<br />

The in<strong>for</strong>mation in the<br />

activated hybrid disk %1<br />

is not updated.<br />

A disk error has been<br />

detected in hybrid<br />

disk %1.<br />

The status of the hybrid<br />

disk %1 is invalid.<br />

Hybrid disk %1 is being<br />

copied.<br />

Hybrid disk %1 has not<br />

been mirrored.<br />

Hybrid disk %1 is<br />

activated on both server<br />

groups.<br />

Hybrid disk to be<br />

monitored is stopped.<br />

Whether the data in<br />

hybrid disk %1 is old or<br />

new has not been<br />

determined.<br />

Message Description Solution<br />

Initialization has<br />

failed[%1!s!].<br />

The configured value is<br />

not correct.<br />

Initialization process has<br />

failed. It may be due to<br />

memory allocation<br />

failure.<br />

In<strong>for</strong>mation on the<br />

initialization may be<br />

displayed on %1.<br />

The configured value of<br />

the monitoring is not<br />

correct.<br />

Memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Memory or OS<br />

resources may not be<br />

sufficient. Check them.<br />

Check the status of the<br />

hybrid disk with Mirror<br />

Disk Helper.<br />

Check that there is no<br />

HW failure in the disk or<br />

disk path where cluster<br />

partition or data partition<br />

exists.<br />

Restart the cluster.<br />

Wait <strong>for</strong> a while until<br />

mirror recovery<br />

completes.<br />

Check the status of the<br />

hybrid disk with Mirror<br />

Disk Helper.<br />

Deactivate the hybrid<br />

disk on one of the<br />

server groups.<br />

Stop the monitor<br />

resource or start the<br />

hybrid disk to be<br />

monitored.<br />

Activate the hybrid disk<br />

on one of the servers.<br />

OS itself may have<br />

errors. Restart the<br />

server or take other<br />

actions.<br />

Check the configured<br />

value on the Builder<br />

since it may not be<br />

<strong>ExpressCluster</strong> X <strong>2.0</strong> <strong>for</strong> <strong>Windows</strong> <strong>Reference</strong> <strong>Guide</strong>