07.11.2014 Views

Application and Optimisation of the Spatial Phase Shifting ...

Application and Optimisation of the Spatial Phase Shifting ...

Application and Optimisation of the Spatial Phase Shifting ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3.4 <strong>Spatial</strong> phase shifting 85<br />

Fig. 3.27: Sawtooth phase maps as results <strong>of</strong> deformation measurement with SPS under: stable experimental<br />

conditions (left), vibrations (centre), <strong>and</strong> air turbulences (right).<br />

3.4.3 Relation <strong>of</strong> speckle size <strong>and</strong> magnification<br />

For usual imaging optics, f# = f/D is confined to a maximum <strong>of</strong> 22 or 32, which may prevent reaching <strong>the</strong><br />

desired d s in some cases. Considering<br />

ds = 122 . λ ( M + 1)<br />

f #<br />

(3.70)<br />

where M is <strong>the</strong> magnification (image size : object size), we can immediately see that <strong>the</strong> maximum object<br />

size that can be imaged gets smaller when d s is to be increased, <strong>and</strong> vice versa. Fig. 3.28 gives an<br />

overview <strong>of</strong> <strong>the</strong> necessary f-numbers when a certain magnification is required. The plots are scaled for <strong>the</strong><br />

pixel size <strong>of</strong> 7.5 µm <strong>of</strong> <strong>the</strong> MX12P camera.<br />

0.01<br />

0.1<br />

M<br />

1<br />

10<br />

100<br />

d s= 0.5 d p<br />

d s = 1 d p<br />

d s = 2 d p<br />

d s = 3 d p<br />

d s =10<br />

1 10 f # 100<br />

Fig. 3.28: Double-logarithmic plot <strong>of</strong> magnification M vs. f-number for various pre-set speckle sizes.<br />

Let us consider a practical example: with a sensor <strong>of</strong> 10241024 pixels, we would need M=0.02 in order<br />

to image (37.5 cm) 2 on <strong>the</strong> chip; for d s =1 pixel, f#10; but for d s =3 d p , f#28, which may not be possible<br />

with st<strong>and</strong>ard imaging optics. It also follows from (3.70) that <strong>the</strong> speckles tend to get very large when<br />

M>1, even for low f# [Løk97, Aebi97]. This is <strong>the</strong> reason why SPS is applicable at no expense in<br />

microscopic ESPI [ElJa99]: <strong>the</strong> speckles are large enough in any case.<br />

d p

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!