<strong>MAN</strong> B&W <strong>Diesel</strong> A/S 6.03<br />
Pumps<br />
Coolers<br />
Page 4 of 5<br />
L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities, S65ME-C/ME-GI, C<strong>on</strong>venti<strong>on</strong>al T/C and central cooling water system<br />
Cyl. 5 6 7 8<br />
, Nominal MCR at 95.0 r/min kW 14,350 17,220 20,090 22,960<br />
Fuel oil circulating pump m3 /h 5.8 6.9 8.1 9.2<br />
Fuel oil supply pump m3 /h 3.6 4.3 5.1 5.8<br />
Jacket cooling pump m3 /h 1) 120 145 165 190<br />
2) 120 145 165 190<br />
3) 120 145 165 190<br />
Central cooling pump* m3 /h 1) 350 415 485 560<br />
2) 350 420 490 560<br />
3) 350 420 490 560<br />
Seawater cooling pump* m3 /h 1) 430 520 600 690<br />
2) 430 520 600 690<br />
3) 430 520 600 690<br />
Main lubricating oil pump* m3 /h 1) 285 340 400 455<br />
2) 285 345 400 455<br />
3)<br />
Scavenge air cooler(s):<br />
285 340 400 455<br />
Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> approx.<br />
Lubricating oil cooler:<br />
kW 5,540 6,650 7,750 8,860<br />
Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> approx.* kW 1) 1,130 1,340 1,570 1,770<br />
2) 1,150 1,420 1,620 1,820<br />
3) 1,120 1,350 1,580 1,790<br />
Lubricating oil flow m3 /h See above ‘Main lubricating oil pump’<br />
Central cooling water qty. m3 /h 1) 155 181 212 248<br />
2) 155 186 217 248<br />
Jacket water cooler:<br />
3) 155 186 217 248<br />
Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> approx. kW 1) 2,080 2,490 2,910 3,320<br />
2) 2,080 2,490 2,910 3,320<br />
3) 2,080 2,490 2,910 3,320<br />
Jacket cooling water qty. m3 /h See above ‘Jacket cooling pump’<br />
Central cooling water qty. m3 Central cooler:<br />
/h See above ‘Central cooling water quantity’ for lube oil<br />
Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> approx.* kW 1) 8,750 10,480 12,230 13,950<br />
2) 8,770 10,560 12,280 14,000<br />
3) 8,740 10,490 12,240 13,970<br />
Central cooling water qty. m3 /h See above ‘Central cooling water pump’<br />
Seawater quantity m3 /h See above ‘Seawater cooling pump’<br />
Fuel oil heater kW 150 180 210 240<br />
Exhaust gas amount at 265º C**<br />
at ISO ambient c<strong>on</strong>diti<strong>on</strong>s kg/h 123,000 147,600 172,200 196,800<br />
Air c<strong>on</strong>sumpti<strong>on</strong> kg/h 33.5 40.2 46.9 53.6<br />
* For main engine arrangements with built-<strong>on</strong> power take-off (PTO) of an <strong>MAN</strong> B&W recommended type and/or torsi<strong>on</strong>al vibrati<strong>on</strong><br />
damper the engine’s capacities must be increased by those stated for the actual system<br />
** The exhaust gas amount and temperature must be adjusted according to the actual plant specificati<strong>on</strong><br />
1) Engines with <strong>MAN</strong> B&W turbochargers, type TCA 3) Engines with Mitsub<str<strong>on</strong>g>is</str<strong>on</strong>g>hi turbochargers<br />
2) Engines with <strong>MAN</strong> B&W turbochargers, type TPL<br />
Fig. 6.03.02b: C<strong>on</strong>venti<strong>on</strong>al turbocharger and central cooling water system stated at the nominal MCR power (L 1 )<br />
for engines complying with IMO’s NO x em<str<strong>on</strong>g>is</str<strong>on</strong>g>si<strong>on</strong> limitati<strong>on</strong>s<br />
S65ME-C/ME-GI 198 48 96-6.1