<strong>MAN</strong> B&W 18.06<br />

Bearing Temperature M<strong>on</strong>itoring System<br />

The Bearing Temperature M<strong>on</strong>itoring (BTM) system<br />

c<strong>on</strong>tinuously m<strong>on</strong>itors the temperature of the<br />

bearing. Some systems measure the temperature<br />

<strong>on</strong> the backside of the bearing shell directly, other<br />

systems detect it by sampling a small part of the<br />

return oil from each bearing in the crankcase.<br />

In case a specified temperature <str<strong>on</strong>g>is</str<strong>on</strong>g> recorded, either<br />

a bearing shell/housing temperature or bearing oil<br />

outlet temperature alarm <str<strong>on</strong>g>is</str<strong>on</strong>g> triggered.<br />

In main bearings, the shell/housing temperature<br />

or the oil outlet temperature <str<strong>on</strong>g>is</str<strong>on</strong>g> m<strong>on</strong>itored depending<br />

<strong>on</strong> how the temperature sensor of the BTM<br />

system, opti<strong>on</strong>: 4 75 1 , <str<strong>on</strong>g>is</str<strong>on</strong>g> installed.<br />

In crankpin and crosshead bearings, the shell/<br />

housing temperature or the oil outlet temperature<br />

<str<strong>on</strong>g>is</str<strong>on</strong>g> m<strong>on</strong>itored depending <strong>on</strong> which BTM system <str<strong>on</strong>g>is</str<strong>on</strong>g><br />

installed, opti<strong>on</strong>s: 4 75 1 4 or 4 75 1 5.<br />

For shell/housing temperature in main, crankpin<br />

and crosshead bearings two high temperature<br />

alarm levels apply. The first level alarm <str<strong>on</strong>g>is</str<strong>on</strong>g> indicated<br />

in the alarm panel while the sec<strong>on</strong>d level<br />

activates a slow down.<br />

For oil outlet temperature in main, crankpin and<br />

crosshead bearings two high temperature alarm<br />

levels including deviati<strong>on</strong> alarm apply. The first<br />

level of the high temperature / deviati<strong>on</strong> alarm <str<strong>on</strong>g>is</str<strong>on</strong>g><br />

indicated in the alarm panel while the sec<strong>on</strong>d level<br />

activates a slow down.<br />

In the Extent of Delivery, there are three opti<strong>on</strong>s:<br />

4 75 1 Temperature sensors fitted to main bearings<br />

4 75 1 4 Temperature sensors fitted to main bearings,<br />

crankpin bearings, crosshead bearings<br />

and for moment compensator, if any<br />

4 75 1 5 Temperature sensors fitted to main bearings,<br />

crankpin bearings and crosshead<br />

bearings<br />

Page 4 of 5<br />

<strong>MAN</strong> B&W ME/ME�C/ME�GI engines 198 67 26�5.1<br />

<strong>MAN</strong> <strong>Diesel</strong>