<strong>MAN</strong> B&W 2.08<br />

SFOC reference c<strong>on</strong>diti<strong>on</strong>s and guarantee<br />

SFOC at reference c<strong>on</strong>diti<strong>on</strong>s<br />

The SFOC <str<strong>on</strong>g>is</str<strong>on</strong>g> given in g/kWh based <strong>on</strong> the<br />

reference ambient c<strong>on</strong>diti<strong>on</strong>s stated in ISO<br />

3046:2002(E) and ISO 5550:2002(E):<br />

,000 mbar ambient air pressure<br />

25 °C ambient air temperature<br />

25 °C scavenge air coolant temperature<br />

and <str<strong>on</strong>g>is</str<strong>on</strong>g> related to a fuel oil with a lower calorific<br />

value of 42,700 kJ/kg (~ 0,200 kcal/kg).<br />

Any d<str<strong>on</strong>g>is</str<strong>on</strong>g>crepancies between g/kWh and g/BHPh<br />

are due to the rounding of numbers for the latter.<br />

For lower calorific values and for ambient c<strong>on</strong>diti<strong>on</strong>s<br />

that are different from the ISO reference<br />

c<strong>on</strong>diti<strong>on</strong>s, the SFOC will be adjusted according<br />

to the c<strong>on</strong>versi<strong>on</strong> factors in the table below.<br />

<strong>MAN</strong> B&W ME/ME-C/ME-GI/ME-B engines<br />

K98MC/MC-C6/7, S90MC-C7/8, K90MC-C6, S80MC6,<br />

S80MC-C7/8, K80MC-C6, S70MC6, S60MC6, S50MC6,<br />

S46MC-C6/7, S42MC7, S35MC7, L35MC6, S26MC6<br />

With<br />

pmax adjusted<br />

SFOC<br />

change<br />

Without<br />

pmax adjusted<br />

SFOC<br />

change<br />

Parameter<br />

C<strong>on</strong>diti<strong>on</strong><br />

change<br />

Scav. air coolant<br />

temperature<br />

per 0 °C r<str<strong>on</strong>g>is</str<strong>on</strong>g>e + 0.60% + 0.4 %<br />

Blower inlet tem-<br />

per 0 °C r<str<strong>on</strong>g>is</str<strong>on</strong>g>e<br />

perature<br />

+ 0.20% + 0.7 %<br />

Blower inlet<br />

pressure<br />

per 0 mbar<br />

r<str<strong>on</strong>g>is</str<strong>on</strong>g>e<br />

� 0.02% � 0.05%<br />

Fuel oil lower<br />

calorific value<br />

r<str<strong>on</strong>g>is</str<strong>on</strong>g>e %<br />

(42,700 kJ/kg)<br />

� .00% � .00%<br />

With for instance °C increase of the scavenge<br />

air coolant temperature, a corresp<strong>on</strong>ding °C increase<br />

of the scavenge air temperature will occur<br />

and involves an SFOC increase of 0.06% if p max <str<strong>on</strong>g>is</str<strong>on</strong>g><br />

adjusted to the same value.<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

SFOC guarantee<br />

Page of 2<br />

The SFOC guarantee refers to the above ISO<br />

reference c<strong>on</strong>diti<strong>on</strong>s and lower calorific value. It<br />

<str<strong>on</strong>g>is</str<strong>on</strong>g> guaranteed for the power�speed combinati<strong>on</strong><br />

in the matching point (O) and the engine running<br />

‘Fuel ec<strong>on</strong>omy mode’ in compliance with IMO NO x<br />

em<str<strong>on</strong>g>is</str<strong>on</strong>g>si<strong>on</strong> limitati<strong>on</strong>s.<br />

The SFOC guarantee <str<strong>on</strong>g>is</str<strong>on</strong>g> given with a tolerance<br />

of 5%<br />

Recommended cooling water temperature<br />

during normal operati<strong>on</strong><br />

In general, it <str<strong>on</strong>g>is</str<strong>on</strong>g> recommended to operate the main<br />

engine with the lowest possible cooling water<br />

temperature to the air coolers, as th<str<strong>on</strong>g>is</str<strong>on</strong>g> will reduce<br />

the fuel c<strong>on</strong>sumpti<strong>on</strong> of the engine, i.e. the engine<br />

performance will be improved.<br />

However, shipyards often specify a c<strong>on</strong>stant<br />

(maximum) central cooling water temperature<br />

of 36 °C, not <strong>on</strong>ly for tropical ambient temperature<br />

c<strong>on</strong>diti<strong>on</strong>s, but also for lower ambient temperature<br />

c<strong>on</strong>diti<strong>on</strong>s. The purpose <str<strong>on</strong>g>is</str<strong>on</strong>g> probably to<br />

reduce the electric power c<strong>on</strong>sumpti<strong>on</strong> of the<br />

cooling water pumps and/or to reduce water c<strong>on</strong>densati<strong>on</strong><br />

in the air coolers.<br />

Thus, when operating with 36 °C cooling water<br />

instead of for example 0 °C (to the air coolers),<br />

the specific fuel oil c<strong>on</strong>sumpti<strong>on</strong> will increase by<br />

approx. 2 g/kWh.<br />