<strong>MAN</strong> B&W <strong>Diesel</strong> A/S 6.04<br />

Page 4 of 12<br />

Nominal rated engine (L 1 ) Example 1<br />

high efficiency Specified MCR (M)<br />

turbochargers (TCA)<br />

Shaft power at SMCR 17,220 kW 14,637 kW<br />

Engine speed at SMCR at 95.0 r/min at 92.2 r/min<br />

Power of matching point %SMCR 100% 90%<br />

Pumps:<br />

Fuel oil circulating pump m 3 /h 6.8 6.8<br />

Fuel oil supply pump m 3 /h 4.3 4.3<br />

Jacket cooling water pump m 3 /h 145 145<br />

Central cooling water pump m 3 /h 430 375<br />

Seawater pump m 3 /h 530 445<br />

Lubricating oil pump m 3 /h 345 345<br />

Coolers:<br />

Scavenge air cooler<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 6,980 5,598<br />

Central water quantity m 3 /h 246 197<br />

Lub. oil cooler<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 1,360 1,315<br />

Lubricating oil quantity m 3 /h 355 355<br />

Central water quantity m 3 /h 184 178<br />

Jacket water cooler<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 2,490 2,189<br />

Jacket cooling water quantity m 3 /h 145 145<br />

Central water quantity m 3 /h 184 178<br />

Central cooler<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> kW 10,830 9,102<br />

Central water quantity m 3 /h 430 375<br />

Seawater quantity m 3 /h 530 445<br />

Fuel oil heater: kW 180 180<br />

Gases at ISO ambient c<strong>on</strong>diti<strong>on</strong>s*<br />

Exhaust gas amount kg/h 159,000 133,600<br />

Exhaust gas temperature °C 245 238.2<br />

Air c<strong>on</strong>sumpti<strong>on</strong> kg/sec. 43.5 36.4<br />

Starting air system: 30 bar (gauge)<br />

Reversible engine<br />

Receiver volume (12 starts) m 3 2 x 7.0 2 x 7.0<br />

Compressor capacity, total m 3 /h 420 420<br />

N<strong>on</strong>-reversible engine<br />

Receiver volume (6 starts) m 3 2 x 3.5 2 x 3.5<br />

Compressor capacity, total m 3 /h 210 210<br />

Exhaust gas tolerances: temperature –/+ 15 °C and amount +/– 5%<br />

The air c<strong>on</strong>sumpti<strong>on</strong> and exhaust gas figures are expected and refer to 100% specified MCR,<br />

ISO ambient reference c<strong>on</strong>diti<strong>on</strong>s and the exhaust gas back pressure 300 mm WC<br />

The exhaust gas temperatures refer to after turbocharger<br />

* Calculated in example 3, in th<str<strong>on</strong>g>is</str<strong>on</strong>g> chapter<br />

Example 1 – Capacities of derated 6S65ME-C with high efficiency <strong>MAN</strong> B&W turbocharger type TCA and<br />

central cooling water system.<br />

S65ME-C 198 48 26-1.1