<strong>MAN</strong> B&W 11.03<br />

Comp<strong>on</strong>ents for Central Cooling Water System<br />

Seawater cooling pumps<br />

The pumps are to be of the centrifugal type.<br />

Seawater flow ......................see ‘L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities’<br />

Pump head ...................................................2.5 bar<br />

Test pressure .................... according to class rules<br />

Working temperature, normal .....................0�32 °C<br />

Working temperature .................... maximum 50 °C<br />

The capacity <str<strong>on</strong>g>is</str<strong>on</strong>g> to be within a tolerance of 0% to<br />

+ 0%.<br />

The differential pressure of the pumps <str<strong>on</strong>g>is</str<strong>on</strong>g> to be determined<br />

<strong>on</strong> the bas<str<strong>on</strong>g>is</str<strong>on</strong>g> of the total actual pressure<br />

drop across the cooling water system.<br />

Central cooler<br />

The cooler <str<strong>on</strong>g>is</str<strong>on</strong>g> to be of the shell and tube or plate<br />

heat exchanger type, made of seawater res<str<strong>on</strong>g>is</str<strong>on</strong>g>tant<br />

material.<br />

Heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> ......................see ‘L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities’<br />

Central cooling water flow ......see ‘L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities’<br />

Central cooling water temperature, outlet ......... 36 °C<br />

Pressure drop <strong>on</strong> central cooling side ....max. 0.2 bar<br />

Seawater flow .........................see ‘L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities’<br />

Seawater temperature, inlet ............................. 32 °C<br />

Pressure drop <strong>on</strong><br />

seawater side ................................ maximum 0.2 bar<br />

The pressure drop may be larger, depending <strong>on</strong><br />

the actual cooler design.<br />

The heat d<str<strong>on</strong>g>is</str<strong>on</strong>g>sipati<strong>on</strong> and the seawater flow figures<br />

are based <strong>on</strong> MCR output at tropical c<strong>on</strong>diti<strong>on</strong>s,<br />

i.e. a seawater temperature of 32 °C and an ambient<br />

air temperature of 45 °C.<br />

Overload running at tropical c<strong>on</strong>diti<strong>on</strong>s will slightly<br />

increase the temperature level in the cooling system,<br />

and will also slightly influence the engine<br />

performance.<br />

Central cooling water pumps<br />

The pumps are to be of the centrifugal type.<br />

Page of 2<br />

Central cooling water flow ....see ‘L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities’<br />

Pump head ...................................................2.5 bar<br />

Delivery pressure ...............depends <strong>on</strong> locati<strong>on</strong> of<br />

expansi<strong>on</strong> tank<br />

Test pressure .................... according to class rules<br />

Working temperature ..................................... 80 °C<br />

Design temperature ..................................... 00 °C<br />

The flow capacity <str<strong>on</strong>g>is</str<strong>on</strong>g> to be within a tolerance of 0%<br />

to + 0%.<br />

The l<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities covers the main engine <strong>on</strong>ly.<br />

The differential pressure provided by the pumps<br />

<str<strong>on</strong>g>is</str<strong>on</strong>g> to be determined <strong>on</strong> the bas<str<strong>on</strong>g>is</str<strong>on</strong>g> of the total actual<br />

pressure drop across the cooling water system.<br />

Central cooling water thermostatic valve<br />

The low temperature cooling system <str<strong>on</strong>g>is</str<strong>on</strong>g> to be<br />

equipped with a three�way valve, mounted as a<br />

mixing valve, which by�passes all or part of the<br />

fresh water around the central cooler.<br />

The sensor <str<strong>on</strong>g>is</str<strong>on</strong>g> to be located at the outlet pipe from<br />

the thermostatic valve and <str<strong>on</strong>g>is</str<strong>on</strong>g> set so as to keep a<br />

temperature level of minimum 0 °C.<br />

<strong>MAN</strong> B&W MC/MC�C, ME/ME-B/ME�C/ME�GI engines 198 39 87�2.3<br />

<strong>MAN</strong> <strong>Diesel</strong>