<strong>MAN</strong> B&W 18.04<br />

Alarms for UMS – Class and <strong>MAN</strong> <strong>Diesel</strong> requirements<br />

ABS<br />

BV<br />

CCS<br />

DNV<br />

GL<br />

KR<br />

LR<br />

NK<br />

RINA<br />

RS<br />

Table 18.04.02b: Alarm functi<strong>on</strong>s for UMS<br />

IACS<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

Page 4 of 7<br />

Sensor and<br />

functi<strong>on</strong> Point of locati<strong>on</strong><br />

Hydraulic Power Supply<br />

XC 23 A Automatic main lube oil filter, failure (Boll & Kirch)<br />

LS 235 AH Leakage oil from hydraulic pipes<br />

LS 236 AH Leakage oil from hydraulic power supply unit<br />

PT 840 AL<br />

Cooling water<br />

Jacket cooling water inlet<br />

PDS/PDT Jacket cooling water across engine; to be calculated<br />

8403 AL in alarm system from sensor no. 8402 and 84 3<br />

TE 8407 AL Jacket cooling water inlet<br />

TE 8408 AH Jacket cooling water outlet, cylinder<br />

PT 84 3 I Jacket cooling water outlet, comm<strong>on</strong> pipe<br />

PT 842 AL Cooling water inlet air cooler<br />

TE 8422 AH Cooling water inlet air cooler/air cooler<br />

PT 850 AL<br />

Compressed air<br />

Starting air inlet to main starting valve<br />

+ PT 8503 AL C<strong>on</strong>trol air inlet and fin<str<strong>on</strong>g>is</str<strong>on</strong>g>hed with engine<br />

PT 8505 AL Air inlet to air cylinder for exhaust valve<br />

PS 8604 AL<br />

Scavenge air<br />

Scavenge air, auxiliary blower, failure (Only ME-B)<br />

÷ TE 8609 AH Scavenge air receiver<br />

TE 86 0 AH Scavenge air box – fire alarm, cylinder/cylinder<br />

LS 86 AH Water m<str<strong>on</strong>g>is</str<strong>on</strong>g>t catcher – water level<br />

Indicates that the sensor <str<strong>on</strong>g>is</str<strong>on</strong>g> required.<br />

The sensors in the <strong>MAN</strong> <strong>Diesel</strong> column are included for Unattended Machinery Spaces (UMS), opti<strong>on</strong>: 4 75 27,<br />

subject to class requirements and will be finally specified in the Guidance Values Automati<strong>on</strong> for the specific<br />

engine plant.<br />

The sensor identificati<strong>on</strong> codes and functi<strong>on</strong>s are l<str<strong>on</strong>g>is</str<strong>on</strong>g>ted in Table 8.07.0 .<br />

The tables are liable to change without notice, and are subject to latest class requirements.<br />

Select <strong>on</strong>e of the alternatives<br />

+ Alarm for high pressure, too<br />

÷ Alarm for low pressure, too<br />

<strong>MAN</strong> B&W ME/ME�C/ME�GI/ME-B engines 198 45 83�8.4<br />