<strong>MAN</strong> B&W 14.02<br />

Auxiliary Blowers<br />

The engine <str<strong>on</strong>g>is</str<strong>on</strong>g> provided with two electrically driven<br />

auxiliary blowers. Between the scavenge air cooler<br />

and the scavenge air receiver, n<strong>on</strong>�return valves<br />

are fitted which close automatically when the auxiliary<br />

blowers start supplying the scavenge air.<br />

The auxiliary blowers start operating c<strong>on</strong>secutively<br />

before the engine <str<strong>on</strong>g>is</str<strong>on</strong>g> started and will ensure<br />

complete scavenging of the cylinders in the starting<br />

phase, thus providing the best c<strong>on</strong>diti<strong>on</strong>s for a<br />

safe start.<br />

During operati<strong>on</strong> of the engine, the auxiliary blowers<br />

will start automatically whenever the engine<br />

load <str<strong>on</strong>g>is</str<strong>on</strong>g> reduced to about 30�40%, and will c<strong>on</strong>tinue<br />

operating until the load again exceeds approximately<br />

40�50%.<br />

Emergency running<br />

If <strong>on</strong>e of the auxiliary blowers <str<strong>on</strong>g>is</str<strong>on</strong>g> out of functi<strong>on</strong>,<br />

the other auxiliary blower will functi<strong>on</strong> in the system,<br />

without any manual adjustment of the valves<br />

being necessary.<br />

�����������������������������<br />

�������������������������<br />

Fig. 14.02.01: Scavenge air system<br />

<strong>MAN</strong> B&W S80ME�C7/8/9, S70ME�C/ME�GI7/8,<br />

L70ME�C7/8, S65ME�C/ME�GI8, S60ME�C/ME�GI7/8,<br />

L60ME�C7/8, S50ME�C7/8<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

C<strong>on</strong>trol of the auxiliary blowers<br />

Page of<br />

The auxiliary blowers are fitted <strong>on</strong>to the main engine.<br />

The c<strong>on</strong>trol system for the auxiliary blowers<br />

<str<strong>on</strong>g>is</str<strong>on</strong>g> integrated in the Engine C<strong>on</strong>trol System.<br />

The starter panels with starters for the auxiliary<br />

blower motors are not included, they can be ordered<br />

as an opti<strong>on</strong>: 4 55 653.<br />

The data for the scavenge air cooler <str<strong>on</strong>g>is</str<strong>on</strong>g> specified in<br />

the descripti<strong>on</strong> of the cooling water system chosen.<br />

For further informati<strong>on</strong>, please refer to our publicati<strong>on</strong><br />

titled:<br />

Influence of Ambient Temperature C<strong>on</strong>diti<strong>on</strong>s<br />

The publicati<strong>on</strong> <str<strong>on</strong>g>is</str<strong>on</strong>g> <str<strong>on</strong>g>available</str<strong>on</strong>g> at: www.mandiesel.com<br />

under ‘Quicklinks’ → ‘Technical Papers’<br />

178 44 70�5.1<br />

198 40 12�4.6