<strong>MAN</strong> <strong>Diesel</strong> 4.06<br />

L16/24 GenSet Data<br />

<strong>MAN</strong> B&W 80 → 26 MC/MC�C, 80 → 50 ME/ME�C,<br />

70 → 60 ME�GI/50 → 35 ME-B<br />

<strong>MAN</strong> <strong>Diesel</strong><br />

Page 3 of 3<br />

Cyl. 5 6 7 8 9<br />

Max c<strong>on</strong>tinues rating 1,200 rpm kW 500 660 770 880 990<br />

Engine driven pumps:<br />

LT cooling water pump 2 bar m³/h 27 27 27 27 27<br />

HT cooling water pump 2 bar m³/h 27 27 27 27 27<br />

Lubricating oil main pump 8 bar m³/h 2 2 35 35 35<br />

Separate pumps:<br />

Max. Delivery pressure of cooling water pumps bar 2.5 2.5 2.5 2.5 2.5<br />

<strong>Diesel</strong> oil pump (5 bar at fuel oil inlet A ) m³/h 0.35 0.46 0.54 0.6 0.69<br />

Fuel oil supply pump (4 bar d<str<strong>on</strong>g>is</str<strong>on</strong>g>charge pressure) m³/h 0. 7 0.22 0.26 0.30 0.34<br />

Fuel oil circulating pump (8 bar at fuel oil inlet A ) m³/h 0.35 0.46 0.54 0.62 0.70<br />

Cooling capacity:<br />

Lubricating oil kW 79 03 22 40 59<br />

Charge air LT kW 40 57 70 82 95<br />

Total LT system kW 9 60 92 222 254<br />

Flow LT at 36°C inlet and 44°C outlet m³/h 3 7 2 24 27<br />

Jacket cooling kW 9 62 9 220 249<br />

Charge air HT kW 23 69 90 2 230<br />

Total HT system kW 242 33 38 43 479<br />

Flow HT at 44°Cinlet and 80°C outlet m³/h 6 8 9 0<br />

Total from engine kW 36 49 573 653 733<br />

LT flow at 36°C inlet m³/h 3 7 2 24 27<br />

LT temp. Outlet engine<br />

(at 36°C and string cooling water system)<br />

°C 60 6 60 60 59<br />

Gas Data:<br />

Exhaust gas flow kg/h 3,400 4,600 5,500 6,200 7,000<br />

Exhaust gas temp. °C 330 340 340 340 340<br />

Max. Allowable back press. bar 0.025 0.025 0.025 0.025 0.025<br />

Air c<strong>on</strong>sumpti<strong>on</strong> kg/h 3,280 4,500 5,300 6,000 6,800<br />

Starting Air System:<br />

Air c<strong>on</strong>sumpti<strong>on</strong> per start Nm 0.47 0.56 0.65 0.75 0.84<br />

Air c<strong>on</strong>sumpti<strong>on</strong> per start Nm 0.80 0.96 . 2 .28 .44<br />

Heat Radiati<strong>on</strong>:<br />

Engine kW 9 3 5 8 2<br />

Alternator kW (see separate data from the alternator maker)<br />

The stated heat balances are based <strong>on</strong> tropical c<strong>on</strong>diti<strong>on</strong>s.The exhaust gas data (exhaust gas flow, exhaust gas temp.<br />

and air c<strong>on</strong>sumpti<strong>on</strong>). are based <strong>on</strong> ISO ambient c<strong>on</strong>diti<strong>on</strong>.<br />

* The outlet temperature of the HT water <str<strong>on</strong>g>is</str<strong>on</strong>g> fixed to 80°C, and 44°C for the LT water<br />

At different inlet temperature the flow will change accordingly.<br />

Example: If the inlet temperature <str<strong>on</strong>g>is</str<strong>on</strong>g> 25°C then the LT flow will change to (44-36)/(44-25)* 00 = 42% of the original flow.<br />

If the temperature r<str<strong>on</strong>g>is</str<strong>on</strong>g>es above 36°C, then the L.T. outlet will r<str<strong>on</strong>g>is</str<strong>on</strong>g>e acordingly.<br />

Fig. 4.06.02b: L<str<strong>on</strong>g>is</str<strong>on</strong>g>t of capacities for L16/24 1,200 rpm<br />

198 42 05�4.4