12.07.2015 Views

Reference Manual - Videx, Inc.

Reference Manual - Videx, Inc.

Reference Manual - Videx, Inc.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Single CyberKey Vault Audit TrailsA set of logs is kept by CyberAudit-Web in response to certain events. Use this log for trackingcheck-out and check-inof the key, activities, and troubleshooting. It is available for each Vaultfrom the drop-down menu in the Vaults page.EventDoor Status Events601 Door opened602 Door closedEvents working with theCyberKeyDescription624 Valid key detected <strong>Inc</strong>ludes name or serial number of the CyberKey.608 PIN required609Error - Key is from adifferent system614 Key type mismatch623Key is not valid forVaultThe card holder requires a PIN for validation and no PIN bypass has beenset. Therefore the Vault cannot issue the key.The detected CyberKey is not valid because it is not a member of thecurrent database and its database flag is set.The detected CyberKey is not valid because it is a CyberLock Programmer,Grand Master, or it does not support the minimum set of features becausethe key is an early model CyberKey.The detected CyberKey failed the validity test.607 Key disabled All access permissions have been removed from the key.606 Key configured A configuration has been sent to the key.605 Key readyThe CyberKey has been programmed and confirmed. The Ready LED isflashing. The key is ready for use.625 Comm error with key The data column contains the error number.628 Low battery629Key does not respondto communications604 Key removedEvents about the RFIDAccess Card630631621611Access approved forcard with no keypresent in VaultAccess approved forcard with invalid keypresent in VaultAccess approved forcard with key presentin VaultNo mission has beenassigned to the cardThe battery level of the CyberKey in the Vault is low. If the key has areplaceable battery it should be changed. If the key has a rechargeablebattery the Charging LED should be on.This could occur if the key's battery is too low to support communications.This allows the card holder to open the door and insert a CyberKey.This allows the card holder to remove the invalid key.The Vault was holding a valid key when the RFID Access card waspresented. CyberAudit-Web then proceeded to program the CyberKey.No mission has been assigned to the card and the Vault properties requirea card mission to program the key and grant access.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!