and communicating with CyberAudit-Web will take noticably longer. In these cases, it is betterto "pre-load" the key records in the Authorizer so the key updates quickly.CyberAudit-Web automatically pre-loads CyberKey records into both Flex System Hubs andWeb Authorizers. LAN Authorizers may be preloaded using the Authorizer Key Associationpage.PIN Use Overrides - Neither Web Stations nor CyberKey Vaults present a way to enter a PIN.Therefore if a key holder or card holder has a PIN it could preclude them from using thosecommunicators. In some cases system administrators may want to bypass that requirement.Vault door details - If a Single CyberKey Vault's door is left open longer than the selectedamount of time, the Vault will emit a low tone beep once every two seconds.The Hold Open Time is the amount of time the Vault's solenoid will hold the latch release openbefore it times out.