Impact Sensitivity<br />

same hardness*). Cylinders and rings are renewed for each falling test<br />

procedure. If the sample is a powder or a paste, the upper cylinder is<br />

slightly pressed into the charged confinement device as far as it will go<br />

without flattening the sample. If liquids are tested, the distance between<br />

the cylinders is 2 mm. The charged device is put on the anvil of<br />

the fallhammer apparatus, and the falling weight, guided by two steel<br />

rods, is unlocked. For sensitive explosives such as primary explosives,<br />

a small fallhammer is used for insensitive explosives a large hammer.<br />

The small hammer involves the use of fall weight of up to 1000 g, while<br />

the fall weights utilized with the large hammer are 1, 5 and 10 kg. The<br />

fall heights are 10–50 cm for the 1-kg weight, 15–50 cm for the 5-kg<br />

weight and 35–50 cm for the 10-kg weight. This method is the recommended<br />

test method in the UN-recommendations for the transport of<br />

dangerous goods and it is standardized as EN 13631-4 as a so-called<br />

Harmonized European Standard.<br />

Fig. 16. Fallhammer confinement device<br />

The influence of friction test results is thus elliminated.<br />

186<br />

* The ground and hardened cylinders and rings are standard parts for ball<br />

bearings; they are available on the market.