09.03.2013 Views

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

173 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

0 to 500 kΩ 0.2071 kΩ<br />

0 to 30 MΩ 0.0012 MΩ<br />

.17 Other<br />

Digital Multimeter<br />

instruments up to 4 ½ digits<br />

@ DC voltage 0 to 100 mV 0.003 mV<br />

0 to 1 V 0.00001 V<br />

0 to 10 V 0.0001 V<br />

0 to 100 V 0.002 V<br />

0 to 1000 V 0.02 V<br />

@ AC voltage 1 to 45 mV 0.003 mV<br />

(from 50 Hz to 20 50 to 450 mV 0.013 mV<br />

kHz) 300 mV to 4.5 V 0.00014 V<br />

5 to 45 V 0.002 V<br />

50 to 1000 V 0.002 V<br />

@ DC current 0 to 330 µA 0.07 µA<br />

0 to 3.3 mA 0.38 mA<br />

0 to 33 mA 2.3 mA<br />

0 to 330 mA 350 mA<br />

0 to 1.1 A 0.00024 A<br />

0 to 3 A 0.0008 A<br />

0 to 20 A 0.0055 A<br />

@ AC current 0 to 500 µA 0.38 µA<br />

(from 50 Hz to 1 0 to 5000 µA 2.3 µA<br />

kHz) 0 to 50 mA 0.035 mA<br />

0 to 400 mA 0.24 mA<br />

0 to 10 A 0.0055 A<br />

@ Resistance 0 to 500 Ω 0.0325 Ω<br />

0 to 5 kΩ 0.0003 kΩ<br />

0 to 50 kΩ 0.003 kΩ<br />

0 to 500 kΩ 0.2071 kΩ<br />

0 to 30 MΩ 0.0012 MΩ<br />

@ Capacitance 0 to 1000 pF 0.069 pF<br />

0 to 10 nF 0.069 nF<br />

0 to 100 nF 0.069 nF<br />

0 to 1000 nF 0.00038 nF<br />

0 to 10 µF 0.0023 µF<br />

0 to 100 µF 0.035 µF<br />

0 to 500 µF 0.00024 µF<br />

0 to 1000 µF 0.0008 µF<br />

5.45 Calibration <strong>of</strong> Ancillary Temperature Me<strong>as</strong>uring Instruments<br />

.04 Indicators,<br />

recorders and<br />

Temperature<br />

Controllers,<br />

Type E T/C<br />

-200 to 1000 °C<br />

0.3 °C<br />

controllers Recorders, Digital<br />

Thermometers<br />

Type J T/C<br />

-200 to 1200 °C<br />

0.8 °C<br />

Type K T/C<br />

-200 to 1370 °C<br />

0.6 °C<br />

Type T T/C<br />

-200 to 400 °C<br />

0.8 °C<br />

5.47 Testing <strong>of</strong> temperature controlled enclosures<br />

.01 Ovens, furnaces<br />

and baths<br />

Ovens Ambient to 150 °C 1.8 °C<br />

5.48 Hygrometer<br />

.01 Calibration <strong>of</strong><br />

humidity<br />

me<strong>as</strong>uring<br />

devices<br />

Thermohygrometer/<br />

Thermohygrograph<br />

20-40 °C<br />

33-96 % R.H<br />

1 °C<br />

4.6 % R.H.<br />

Standard Method/<br />

Reference<br />

Standard<br />

Manufacturer’s<br />

recommended<br />

Calibration method<br />

& In-house<br />

Procedure IMI-CCL.<br />

(EA-10/15: January<br />

2001)<br />

In-house/On-Site<br />

Calibration<br />

B<strong>as</strong>ed on in-house<br />

procedure IMI-CCL<br />

05 007<br />

In-house/On-Site<br />

Calibration<br />

B<strong>as</strong>ed on in-house<br />

procedure IMI-CCL<br />

99 006<br />

B<strong>as</strong>ed on in-house<br />

procedure IMI-CCL<br />

00 001

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!