Accreditation No. Field <strong>of</strong> Testing<br />

LA-2006-086B Calibration<br />

Validity: 05 June 2014<br />

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

385 <strong>of</strong> 391<br />

Best me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

Standard Method/<br />

Reference<br />

Standard<br />

5.03 Engineering metrology equipment<br />

.22 Electronic and Calibration <strong>of</strong> Digital 0 to 150mm ± 7 µm In-house calibration<br />

vernier calipers Calipers 0 to 200mm ± 9 µm QMP-07-L-001<br />

0 to 300mm ± 11 µm<br />

Calibration <strong>of</strong> Analog 0 to 150mm ± 20 µm<br />

Calipers 0 to 200mm ± 21 µm<br />

0 to 300mm ± 22 µm<br />

.28 Other me<strong>as</strong>uring Calibration <strong>of</strong> Digital 0 to 25mm ±0.8 µm In-house calibration<br />

instruments and External/Outside 25 to 50mm ±1.1 µm QMP-07-L-002<br />

tools Micrometers 50 to 75mm ±1.3 µm<br />

75 to 100 mm ±1.6 µm<br />

100 to 125mm ±1.9 µm<br />

Calibration <strong>of</strong> Analog 0 to 25mm ±2.3 µm<br />

External/Outside 25 to 50mm ±2.4 µm<br />

Micrometers 50 to 75mm ±2.5 µm<br />

75 to 100 mm ±2.7 µm<br />

100 to 125mm ±2.9 µm<br />

5.11 Weighing devices<br />

.01 Precision<br />

Laboratory<br />

Balances<br />

Calibration <strong>of</strong><br />

Analytical Balance<br />

10 g to 1kg ± 0.1 mg to 0.8 mg Onsite calibration<br />

QMP-07-B-001<br />

VD-07-003<br />

.02 Industrial Calibration <strong>of</strong> 10 g to 1kg ± 0.1 mg to 0.8 mg<br />

Balance Industrial Balance 1kg to 300 kg ±0.008 g to 20g<br />

.05 Other Weighing Calibration <strong>of</strong> 10 g to 1kg ± 0.1 mg to 0.8 mg<br />

Devices Weighing Scales 1kg to 300 kg ±0.008 g to 20g<br />

5.20 Pressure and vacuum me<strong>as</strong>uring devices<br />

.01 Pressure Calibration <strong>of</strong> 0 to 300 psi ± 0.1 % FS In-house/ Onsite<br />

gauges Pressure gauges >300 to 10000<br />

psi<br />

± 0.7 % FS calibration<br />

.02 Vacuum gauges Calibration <strong>of</strong><br />

0 to –30 in Hg ± 0.7 % FS QMP-07-P-002<br />

Vacuum gauges<br />

VD-07-004<br />

.07 Digital<br />

Manometer<br />

Calibration <strong>of</strong> Digital<br />

Manometers<br />

0 to 300 psi ±0.01% reading<br />

In-house calibration<br />

QMP-07-P-007<br />

5.21 Pressure gauge testers<br />

.03 Pressure<br />

Calibrators<br />

Calibration <strong>of</strong><br />

Pressure Calibrators<br />

0 to 300 psi ±0.01% <strong>of</strong> reading<br />

In-house calibration<br />

QMP-07-P-007<br />

5.34 Instrument calibrators<br />

.01 DC Voltage Calibration <strong>of</strong> DC 0 to 100 mV ±0.002% reading In-house calibration<br />

Voltage Source 0 to 1 V ±0.001% reading QMP-07-E-016<br />

0 to 10 V ±0.001% reading<br />

0 to 60 V ±0.001% reading<br />

.03 DC Current Calibration <strong>of</strong> DC 0 to 100 µA ±0.001 % reading In-house calibration<br />

Current Source 0 to 1 mA ±0.001 % reading QMP-07-E-020<br />

0 to 10 mA ±0.001 % reading<br />

0 to 100 mA ± 0.001 % reading<br />

.05 Resistance Calibration <strong>of</strong> 0 to 10 ± 0.003 % reading In-house calibration<br />

Resistance Source 0 to 100 ± 0.002 % reading QMP-07-E-017<br />

0 to 4 k ± 0.002 % reading