09.03.2013 Views

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be calibrated<br />

274 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

100 g ± 0.33 mg<br />

OIML Cl<strong>as</strong>s M2, 200 g ± 1.4 mg<br />

M3 500 g ± 87 mg<br />

M<strong>as</strong>s Standards 1 kg ± 81 mg<br />

2 kg ± 0.13 g<br />

5 kg ± 1.2 g<br />

10 kg ± 1.2 g<br />

OIML Cl<strong>as</strong>s M3 20 kg ± 1.3 g<br />

M<strong>as</strong>s Standards<br />

5.11 Weighing Devices<br />

25 kg ± 1.4 g<br />

.01 Precision Precision<br />

0 to 1 g ± 0.015 mg to<br />

Laboratory Laboratory<br />

0.026 mg<br />

Balances Balances 1 g to 20 g ± 0.026 mg to<br />

0.04 mg<br />

20 g to 180 g ± 0.04 mg to 0.26<br />

mg<br />

Standard Method/<br />

Reference<br />

Standard<br />

Attached CD-WI-025<br />

(Cl<strong>as</strong>s F1, F2, M2,<br />

M3 Weights)<br />

In-House/On-Site<br />

Calibration<br />

180 g to 480 g ± 0.26 mg to 1.2<br />

mg<br />

480 g to 1 200 g ± 1.2 mg to 12<br />

mg<br />

1 200 g to 1 800 g ± 12 mg to 37 mg<br />

1.8 kg to 3 kg ± 37 mg to 0.10 g<br />

.02 Industrial Industrial 0 to 1 800 g ± 12 mg to 37 mg Attached CD-WI-025<br />

Balances Balance 1 800 g to 5 400 g ± 37 mg to 0.07 g (Cl<strong>as</strong>s F1, F2, M2,<br />

5.4 kg to 15 kg ± 0.07 g to 0.14 g M3 Weights)<br />

15 kg to 30 kg ± 0.14 g to 0.82 g In-House/On-Site<br />

30 kg to 60 kg ± 0.82 g to 2.9 g Calibration<br />

60 kg to 100 kg ± 2.9 g to 11 g<br />

5.20 Pressure and Vacuum Me<strong>as</strong>uring Devices<br />

.01 Pressure Pressure Gauges 0 to 60 psi 0.18 psi Non-Std. Method<br />

Gauges 60. to 180 psi 0.52 psi CD-WI-018<br />

180 to 260 psi 0.75 psi On-Site Calibration<br />

260 to 380 psi 1.1 psi<br />

380 to 500 psi 1.4 psi<br />

500 to 600 psi 1.7 psi<br />

500 to 1 000 psi 3.2 psi<br />

1 000 to 2 000 psi 5.8 psi<br />

2 000 to 5 000 psi 14 psi<br />

.02 Vacuum<br />

Gauges<br />

5 000 to 10 000 psi 28 psi<br />

Vacuum Gauges 0 to 30 inHg<br />

0.32 inHg<br />

Non-Std. Method<br />

CD-WI-018<br />

On-Site Calibration<br />

5.34 Electrical Instrument Calibrators<br />

.01 DC Voltage DC Voltage<br />

Calibrators /<br />

Sources<br />

200 mV to 200 V 0.000 57 V<br />

Non Std. Method<br />

CD-WI-040<br />

.03 DC Current DC Current<br />

Calibrators /<br />

Sources<br />

1 uA to 1 A<br />

0.000 071 A<br />

.05 Resistance Resistance<br />

Calibrators /<br />

Sources<br />

20 Ω to 200 MΩ 0.000 059 MΩ<br />

Non Std. Method<br />

CD-WI-040<br />

.08 Frequency Frequency<br />

Sources<br />

20 Hz to 40 kHz 0.000 58 kHz<br />

5.35 Indicating and recording instrument (6 ½ digit Digital Multimeter)<br />

.01 DC voltmeters DC Voltmeters 0 to 100 mV 0.002 mV Non-Std. Method<br />

100 mV to 1 V 0.000 008 4V CD-WI-006 /<br />

1 V to 10 V 0.000 06 V CD-WI-007 /<br />

10 V to 100 V 0.000 78 V CD-WI-008 /<br />

100 V to 1000 V 0.009 8 V CD-WI-009 /<br />

.02 AC voltmeters AC Voltmeters 0 to 10 mV @ 1 kHz 0.004 3 mV CD-WI-010 /<br />

0 to 100 mV @ 1 kHz 0.029 mV CD-WI-026

Hooray! Your file is uploaded and ready to be published.