Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

303 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

Standard Method/<br />

Reference Standard<br />

10ms 1.04ms<br />

5ms 0.051ms<br />

2ms 0.021ms<br />

1ms 0.010ms<br />

0.5ms 5.218ms<br />

0.2ms 2.088ms<br />

0.1ms 1.043ms<br />

50µs 0.522µs<br />

20µs 0.209µs<br />

10µs 0.104µs<br />

5µs 0.051µs<br />

2µs 0.021µs<br />

1µs 0.01µs<br />

0.5µs 5.218µs<br />

0.2µs 2.088µs<br />

0.1µs 1.043µs<br />

50ŋs 0.522ŋs<br />

20ŋs 0.209ŋs<br />

10ŋs 0.104ŋs<br />

5ŋs 0.051ŋs<br />

5.42 High voltage equipment<br />

.01 Direct voltage Direct voltage/<br />

Up to 10kV 0.13% In-House / On-Site<br />

tests<br />

high voltage tester<br />

Calibration<br />

.02 Alternating Alternating<br />

Up to 10kV 0.21%<br />

SSS-CP-038<br />

voltage tests voltage/ high<br />

voltage tester<br />

(By Direct Comparison)<br />

.06 Dielectric tests Dielectric test/<br />

high voltage tester<br />

Up to 10kV 0.21%<br />

5.44 Calibration <strong>of</strong> temperature me<strong>as</strong>urement equipment<br />

.02 B<strong>as</strong>e metal B<strong>as</strong>e metal<br />

-10°C to 300°C ±1.0°C In-House Calibration<br />

thermocouples thermocouple<br />

SSS-CP-057<br />

(By Direct Comparison)<br />

.04 Metallic Platinum and -10°C to 300°C ±1.0°C In-House Calibration<br />

resistance other metallic<br />

SSS-CP-059<br />

thermometers resistance<br />

thermometer<br />

(By Direct Comparison)<br />

.06 Liquid-in-gl<strong>as</strong>s Liquid-in-gl<strong>as</strong>s -10°C to 200°C ±1.0°C In-House Calibration<br />

thermometers thermometer<br />

SSS-CP-014<br />

(By Direct Comparison)<br />

.09 Vapour Vapor pressure -10°C to 200°C ±1.0°C In-House Calibration<br />

pressure thermometer<br />

SSS-CP-056<br />

thermometers<br />

(By Direct Comparison)<br />

.10 Filled metal Filled metal<br />

-10°C to 300°C ±1.0°C In-House Calibration<br />

systems systems<br />

SSS-CP-058<br />

(By Direct Comparison)<br />

.11 Bimetallic Bimetallic systems -10°C to 300°C ±1.0°C In-House Calibration<br />

systems<br />

SSS-CP-056<br />

(By Direct Comparison)<br />

5.45 Temperature me<strong>as</strong>uring instrument<br />

.04 Indicators, Indicators,<br />

T/C -200°C to<br />

0.75°C In-House / On-Site<br />

recorders and recorders and<br />

1370°C<br />

Calibration<br />

controllers controllers RTD -200°C to<br />

0.46°C SSS-CP-003, 015<br />

800°C<br />

(By Direct Comparison)<br />

.08 Other<br />

Temperature<br />

T/C -200°C to<br />

0.75°C In-House / On-Site<br />

equipment calibrators<br />

1370°C<br />

Calibration<br />

RTD -200°C to<br />

0.46°C SSS-CP-046<br />

800°C<br />

(By Direct Comparison)<br />

5.47 Testing <strong>of</strong> temperature controlled enclosures<br />

.01 Ovens and Ovens and baths 0 to 500°C 1.23°C In-House / On-Site<br />

furnaces, bath Furnaces 50 to 1000°C 3°C Calibration<br />

.02 Incubators Incubators 0 to 200°C 1.23°C SSS-CP-004<br />

.03 Autoclaves Autoclaves 0 to 300°C 1.23°C (By Direct Comparison)