192. TUV RHEINLAND PHILIPPINES, INC. – PHILIPPINE LABORATORY<br />

Address : Unit 8, La Fuerza Plaza I, 2241 Don Cheno Roces Ave., 1231<br />

Makati City, Philippines<br />

Telephone No. : (632) 812-5339/ 812-5147<br />

Fax No. : (632) 812-5227<br />

E-mail : psq@phl.tuv.com or Tristan.Loveres@phl.tuv.com<br />

Authorized Representative : Mr. Tristan Arwen G. Loveres<br />

Manager, GB Products<br />

Accreditation No. Field <strong>of</strong> Testing<br />

LA-2009-158A Electrical Testing<br />

Validity: 06 <strong>Dec</strong>ember 2014<br />

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Specific tests or<br />

Me<strong>as</strong>urements<br />

375 <strong>of</strong> 391<br />

Standard Method/<br />

Reference Standard<br />

3.37 Approval tests on electrical appliances, accessories and tools<br />

Electric Irons<br />

Clause 7 Markings and instruction<br />

PNS 1079:1994<br />

(Except pressurized<br />

steam Iron)<br />

Clause 8 Protection against access to live part<br />

Clause 10 Power Input and current<br />

(IEC 335-1:1991)<br />

Clause 11 Heating PNS 254-1:1994<br />

Clause 13 Leakage current and electric strength at<br />

operating temperature<br />

Clause 15 Moisture resistance<br />

Clause 16 Leakage current and electric strength<br />

Clause 17 Overload protection <strong>of</strong> transformers and<br />

<strong>as</strong>sociated circuits<br />

Clause 18 Endurance<br />

Clause 19 Abnormal operation<br />

Clause 20 Stability and mechanical hazard<br />

Clause 21 Mechanical strength<br />

Clause 22 Construction<br />

Clause 23 Internal wiring<br />

Clause 25 Supply connection and external flexible cords<br />

Clause 26 Terminals for external conductors<br />

Clause 27 Provision for earthing<br />

Clause 28 Screws and connections<br />

Clause 29 Creepage distances, clearances and distances<br />

through insulation<br />

Clause 30 Resistance to heat and fire<br />

Clause 31 Resistance to rusting<br />

Clause 32 Radiation, toxicity and similar hazards<br />

(IEC 335-2-3:1993)<br />

W<strong>as</strong>hing machine Clause 7 Markings and instruction PNS 1079:1994<br />

Clause 8 Protection against access to live part<br />

Clause 10 Power Input and current<br />

(IEC 335-1:1991)<br />

Clause 11 Heating PNS IEC 60335-2-<br />

Clause 13 Leakage current and electric strength at<br />

7:2000<br />

operating temperature<br />

Clause 15 Moisture resistance<br />

Clause 16 Leakage current and electric strength<br />

Clause 17 Overload protection <strong>of</strong> transformers and<br />

<strong>as</strong>sociated circuits<br />

Clause 19 Abnormal operation<br />

Clause 20 Stability and mechanical hazard<br />

Clause 21 Mechanical strength<br />

Clause 22 Construction<br />

Clause 23 Internal wiring<br />

Clause 25 Supply connection and external flexible cords<br />

Clause 26 Terminals for external conductors<br />

Clause 27 Provision for earthing<br />

Clause 28 Screws and connections<br />

Clause 29 Creepage distances, clearances and distances<br />

through insulation<br />

Clause 30 Resistance to heat and fire<br />

Clause 31 Resistance to rusting<br />

(IEC 335-2-7:1993)