PAO Accredited Laboratories (as of Dec. 2012) - DTI
PAO Accredited Laboratories (as of Dec. 2012) - DTI
PAO Accredited Laboratories (as of Dec. 2012) - DTI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
189. SYCWIN WIRE & CABLE TECHNICAL LABORATORY<br />
Address : 93 Joy St., Garce Village, Balintawak, Quezon City 1115<br />
Philippines<br />
Telephone No. : 364-6001 to 06<br />
Fax No. : 364-3870<br />
E-mail : swctl@sycwin.com<br />
Authorized Representative : Ms. Marites P. Templonuevo<br />
Laboratory Manager<br />
Accreditation No. Field <strong>of</strong> Testing<br />
LA-<strong>2012</strong>-223A Electrical Testing<br />
Validity: 15 July 2017<br />
Products/<br />
Cl<strong>as</strong>s <strong>of</strong> Test<br />
Specific tests or<br />
Me<strong>as</strong>urements<br />
370 <strong>of</strong> 391<br />
Standard Method/<br />
Reference Standard<br />
3.01 Conducting materials, conductors and resistance alloys<br />
.01 Resistivity and conductivity<br />
Thermopl<strong>as</strong>tic insulated copper<br />
wires and cables rated 600 volts<br />
(TW, THW, THHN/THWN)<br />
Electrical conductivity PNS 35-1:2004 Clause 4.1.1<br />
Annealed Copper Wires Resistivity PNS 260:2004 Clause 5.3.2, 5.3.3<br />
Electrical conductivity ASTM B3: 2007 Clause 6.2<br />
Telephone Drop Wires<br />
Electrical conductivity ASTM B227:2010 Clause 9.1 to 9.4<br />
(Copper and Copper Clad only)<br />
.04 Physical properties<br />
ASTM B1: 2007 Clause 6.2<br />
Thermopl<strong>as</strong>tic insulated copper<br />
wires and cables rated 600 volts<br />
(TW, THW, THHN/THWN)<br />
Conductor diameter/area PNS 35-1:2004 Clause 4.1.1<br />
Annealed Copper Wires Wire diameter PNS 260:2004 Clause 5.1<br />
ASTM B3: 2007 Clause 6.3<br />
Stranded Copper Wires Wire diameter area PNS 1207:2006 Clause 4.3, 4.4.3<br />
ASTM B8: 2004 Clause 12.1, 11.1<br />
Lay length/Lay ratio PNS 1207:2006 Clause 4.4.2<br />
ASTM B8: 2004 Clause 5.3<br />
Lay direction PNS 1207:2006 Clause 4.4.2<br />
ASTM B8: 2004 Clause 5.5<br />
Polyvinyl Chloride Insulated Conductor diameter /area PNS 163:1994 Clause 4.3.1<br />
Flexible Cords (SJT/ST, TF)<br />
PNS 163:2007 Clause 4.3.1<br />
Telephone Drop Wires<br />
Diameter <strong>of</strong> conductor ASTM B227:2010 Clause 5.1, 5.2<br />
(Copper and Copper Clad only)<br />
ASTM B1: 2007 Clause 6.3<br />
Telephone Jacketed Wires<br />
(2, 3 & 4 Conductors)<br />
3.23 Cables and feeders<br />
.01 Conductor resistance tests<br />
Conductor diameter/area PNS 260: 2004 Clause 5.1<br />
Thermopl<strong>as</strong>tic insulated copper<br />
wires and cables rated 600 volts<br />
(TW, THW, THHN/THWN)<br />
Conductor resistance PNS 35-1:2004 Clause 4.1.1<br />
Annealed Copper Wires Conductor Resistance PNS 260:2004 Clause 5.3.1<br />
ASTM B3: 2007 Clause 6.2<br />
Stranded Copper Wires Conductor resistance PNS 1207:2006 Clause 4.4.5,<br />
4.4.5.1, 4.4.5.2 ;<br />
ASTM B8: 2004 Clause 10.1, 10.2<br />
Telephone Drop Wires<br />
Conductor resistance ASTM B227:2010 Clause 9.1 to 9.4<br />
(Copper and Copper Clad only)<br />
ASTM B1: 2007 Clause 6.2<br />
Telephone Jacketed Wires Conductor resistance PNS 260: 2004 Clause 5.3.1<br />
(2, 3 & 4 Conductors)<br />
.02 Insulation resistance tests<br />
Electrical conductivity PNS 260: 2004 Clause 5.3.2, 5.3.2<br />
Thermopl<strong>as</strong>tic insulated copper Insulation resistance PNS 35-1:2004 Clause 5.3, 5.3.1 to<br />
wires and cables rated 600 volts<br />
(TW, THW, THHN/THWN)<br />
5.3.4<br />
Polyvinyl Chloride Insulated Insulation resistance PNS 163:1994 Annex D<br />
Flexible Cords (SJT/ST, TF)<br />
PNS 163:2007 Annex D<br />
Telephone Drop Wires<br />
Insulation resistance PNS 35-1:2004 Clause 5.3.1 to<br />
(Copper and Copper Clad only)<br />
5.3.3<br />
Telephone Jacketed Wires<br />
Insulation resistance PNS 35-1:2004 Clause 5.3, 5.3.1 to<br />
(2, 3 & 4 Conductors)<br />
5.3.3