188. SUBIC DRYDOCK CORPORATION<br />

Address : Bldg. 17 Gridley Corner Schley Roads, SRF Compound<br />

Subic Bay Freeport Zone, Philippines 2222<br />

Telephone No. : (047) 252-8183<br />

Fax No. : (047) 252-8201<br />

E-mail : info@subicdock.com<br />

Authorized Representative : Mr. Potenciano V. Sancon<br />

Quality and Safety Manager<br />

Accreditation No. Field <strong>of</strong> Testing<br />

LA-2011-204A Calibration<br />

Validity: 24 November 2016<br />

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

369 <strong>of</strong> 391<br />

Best me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

Standard Method/<br />

Reference<br />

Standard<br />

5.03 Engineering metrology equipment<br />

.18 Internal/ Internal 0 to 8 in ±0.001 in In House<br />

External Micrometers 0 to 200 mm ±0.0254 mm QAP-C-303<br />

micrometers External 0 to 9 in ±0.000118 in In House<br />

.22 Electronic/<br />

vernier/dial<br />

Micrometers 0 to 225 mm ±0.003 mm QAP-C-304<br />

Electronic/<br />

vernier/dial<br />

0 to 12 in ±0.00134 in In House<br />

QAP-C-305<br />

0 to 300 mm ±0.034 mm<br />

calipers<br />

calipers<br />

5.20 Pressure and Me<strong>as</strong>uring Devices<br />

.01 Pressure Pneumatic 0 to 100 psig ± 1% <strong>of</strong> full-scale In House<br />

Gauges Pressure Gauges 0 to 2,000 psig ± 1% <strong>of</strong> full-scale QAP-C-301<br />

Hydraulic Pressure 0 to 1,000 psig ± 1% <strong>of</strong> reading In House<br />

Gauges<br />

0 to 10,000 psig ± 1% <strong>of</strong> reading<br />

QAP-C-301 /<br />

QAP-C-307<br />

.02 Vacuum Vacuum Gauges 0 to 30 in Hg ± 2% <strong>of</strong> full-scale In House<br />

Gauges<br />

QAP-C-302<br />

5.44 Calibration <strong>of</strong> temperature me<strong>as</strong>urement equipment<br />

.11 Bimetallic<br />

systems<br />

Bimetallic -25°C to +150°C<br />

± 1 °C In House<br />

QAP-C-306<br />

* A reported uncertainty will be that for the instrument itself during calibration plus the appropriate<br />