162. PREMIER PHYSIC METROLOGIE CO.<br />

Address : Unit A, JL Building, Doña Soledad Ave., Extension, Better<br />

Living Subdivision, Parañaque City, 1700<br />

Telephone No. : (632) 776-5280<br />

Fax No. : (632) 776-5280<br />

E-mail : metrology@ppmcalab.com<br />

Authorized Representative : Mr. Roxan L. Rox<strong>as</strong><br />

Technical Manager<br />

Accreditation No. Field <strong>of</strong> Testing<br />

LA-2007-112B<br />

Calibration<br />

Validity: 23 July 2015<br />

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

280 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

Standard Method/<br />

Reference Standard<br />

5.03 Engineering Metrology Equipment<br />

.18 External Calibration <strong>of</strong> External 0 to 25 mm ± 2 µm In-house calibration<br />

Micrometers Micrometers<br />

PPM CAL 307<br />

.20 Electronic Calibration <strong>of</strong><br />

0 to 50 mm ± 1.5 µm In-house calibration<br />

Indicators, Dial Electronic Indicators,<br />

PPM CAL 311<br />

Gauges Dial Gauges<br />

.22 Electronic and Calibration <strong>of</strong> Vernier 0 to 300 mm ± 14 µm In-house calibration<br />

Vernier and Digimatic<br />

PPM CAL 306<br />

Calipers Calipers<br />

.24 Feeler Gauges Calibration <strong>of</strong> Feeler 0.1 to 1 mm<br />

± 2.6 µm In-house calibration<br />

Gauges<br />

PPM CAL 309<br />

5.11 Weighing Devices<br />

.01 Precision Calibration <strong>of</strong><br />

up to 320 g<br />

± 0.01 mg In-house calibration /<br />

Laboratory Precision Laboratory<br />

On-site calibration<br />

Balances Balances<br />

PPM CAL 316<br />

.02 Industrial Calibration <strong>of</strong><br />

up to 3 ton ± 1 mg<br />

balances Industrial<br />

Balances<br />

.03 Industrial Calibration <strong>of</strong><br />

up to 3 ton ± 0.215 mg<br />

Weighing Industrial<br />

Appliances Weighing Appliances<br />

5.12 Volumetric Equipment<br />

.01 Volumetric Calibration <strong>of</strong> Burette up to 100 ml ± 0.005 ml In-house calibration<br />

Gl<strong>as</strong>sware Calibration <strong>of</strong> Pipette up to 200 ml ± 0.003 ml PPM CAL 339<br />

Calibration <strong>of</strong><br />

Volumetric Pipette<br />

up to 200 ml ± 0.003 ml<br />

Calibration <strong>of</strong><br />

Graduated Pipette<br />

up to 200 ml ± 0.003 ml<br />

Calibration <strong>of</strong><br />

Graduated Cylinder<br />

up to 1 000 ml ± 0.01 ml<br />

Calibration <strong>of</strong><br />

Volumetric Fl<strong>as</strong>k<br />

up to 1 000 ml ± 0.01 ml<br />

.02 Special Calibration <strong>of</strong> Special up to 200 ml ± 0.004 ml In-house calibration<br />

Laboratory Laboratory Volumetric<br />

PPM CAL 339<br />

Volumetric<br />

Apparatus<br />

Apparatus<br />

5.20 Pressure and Vacuum Me<strong>as</strong>uring Devices<br />

.01 Pressure Calibration <strong>of</strong><br />

0 to 5 000 mbar ± 0.67 psi In-house calibration /<br />

Gauges Pressure Gauges<br />

On-site calibration<br />

.02 Vacuum Calibration <strong>of</strong> Vacuum 0 to 30 inHg ± 1 inHg PPM CAL 322<br />

Gauges Gauges<br />

PPM CAL 324<br />

.03 Pressure Calibration <strong>of</strong><br />

0 to 5 000 psi ± 0.67 psi<br />

Transducers Pressure Transducers<br />

.04 Pressure Calibration <strong>of</strong><br />

0 to 5 000 psi ± 0.67 psi<br />

Recorders Pressure Recorders<br />

.07 Digital<br />

Calibration <strong>of</strong> Digital 0 to 5 000 psi ± 0.57 psi<br />

Manometers Manometers