Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

.08 Pressure<br />

Control Devices<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Calibration <strong>of</strong><br />

Pressure Control<br />

Devices<br />

5.22 Force Me<strong>as</strong>uring Devices<br />

.03 Load Cells Calibration <strong>of</strong> Load<br />

Cells<br />

.04 Force Gauges<br />

@ pull<br />

function only<br />

Calibration <strong>of</strong> Force<br />

Gauges @ pull<br />

function only<br />

5.24 Torque Me<strong>as</strong>uring Devices<br />

.01 Torque<br />

Wrenches /<br />

Drivers<br />

Calibration <strong>of</strong> Torque<br />

Wrenches / Drivers<br />

Range to be<br />

calibrated<br />

281 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

0 to 5 000 psi ± 0.57 psi<br />

Standard Method/<br />

Reference Standard<br />

up to 100 kgf ± 5.78 gf In-house calibration /<br />

On-site calibration<br />

PPM CAL 346<br />

up to 100 kgf ± 5.78 gf In-house calibration /<br />

On-site calibration<br />

PPM CAL 302<br />

up to 100 kgf-cm ± 0.15 kgf-cm In-house calibration /<br />

On-site calibration<br />

PPM CAL 331<br />

5.27 Ancillary Testing Equipment for Construction Materials<br />

.02 Ovens Calibration <strong>of</strong> Ovens Ambient to 250 °C ± 0.4 °C In-house calibration /<br />

On-site calibration<br />

.04 Vicat<br />

Calibration <strong>of</strong> Vicat 0 to 50 mm ± 0.134 mm<br />

PPM CAL 329<br />

In-house calibration /<br />

Apparatus Apparatus<br />

PPM CAL 352<br />

5.44 Calibration <strong>of</strong> temperature me<strong>as</strong>urement equipment<br />

.06 Liquid-in-Gl<strong>as</strong>s Calibration <strong>of</strong> Liquid- 0 to 200 °C ± 0.27 °C In-house calibration<br />

Thermometer in-Gl<strong>as</strong>s<br />

Thermometers<br />

PPM CAL 326<br />

.09 Vapor Pressure Calibration <strong>of</strong> Vapour - 15 to 600 °C ± 0.27 °C In-house calibration /<br />

Thermometer Pressure<br />

On-site calibration<br />

Thermometers<br />

PPM CAL 327<br />

.10 Filled Metal Calibration <strong>of</strong> Filled - 15 to 600 °C ± 27 °C<br />

Systems Metal Systems<br />

.11 Bimetallic Calibration <strong>of</strong><br />

- 15 to 600 °C ± 27 °C<br />

Systems Bimetallic Systems<br />

.13 Digital<br />

Calibration <strong>of</strong> Digital - 15 to 800 °C ± 28 °C<br />

Temperature Temperature Indicator<br />

Indicator<br />

Systems<br />

Systems<br />

5.45 Calibration <strong>of</strong> Ancillary Temperature Me<strong>as</strong>uring Instrument<br />

.04 Indicators, Calibration <strong>of</strong><br />

-40 to 1 000 °C ± 0.3 °C In-house calibration /<br />

Recorders and Temperature<br />

On-site calibration<br />

Controllers Indicators, Recorders<br />

and Controllers (T/C<br />

and RTD)<br />

PPM CAL 346-A<br />

.05 Temperature Calibration <strong>of</strong><br />

-40 to 600 °C ± 1 °C In-house calibration /<br />

Transmitters Temperature<br />

On-site calibration<br />

Transmitters (T/C and<br />

RTD)<br />

PPM CAL 357<br />

5.46 Calibration <strong>of</strong> Clinical Thermometers<br />

.01 Liquid-in-Gl<strong>as</strong>s Calibration <strong>of</strong> Liquid- 0 to 200 °C ± 0.24 °C In-house calibration<br />

in-Gl<strong>as</strong>s<br />

PPM CAL 347<br />

.03 Electronic Calibration <strong>of</strong><br />

0 to 200 °C ± 0.24 °C In-house calibration<br />

Electronic<br />

Thermometers<br />

PPM CAL 348<br />

5.47 Testing <strong>of</strong> Temperature Controlled Enclosures<br />

.01 Ovens, Calibration <strong>of</strong> Ovens Ambient to 250 °C ± 0.4 °C In-house calibration /<br />

Furnaces and and Baths<br />

On-site calibration<br />

Baths<br />

Calibration <strong>of</strong><br />

Furnaces<br />

Ambient to 800 °C ± 4 °C<br />

PPM CAL 329<br />

.02 Incubators Calibration <strong>of</strong><br />

Incubators<br />

Ambient to 250 °C ± 0.4 °C<br />

.03 Autoclaves and Calibration <strong>of</strong><br />

Ambient to 250 °C ± 0.4 °C<br />

Sterilizing Autoclaves and<br />

Ovens<br />

Sterilizing Ovens<br />

.04 Industrial Calibration <strong>of</strong><br />

- 15 °C to Ambient ± 0.4 °C<br />

Freezers Industrial Freezers