09.03.2013 Views

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

PAO Accredited Laboratories (as of Dec. 2012) - DTI

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

.17 Other<br />

instruments<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Range to be<br />

calibrated<br />

232 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

1 k 0.0002%<br />

10 k 0.001%<br />

100 k 0.001%<br />

1 M 0.002%<br />

10 M 0.004%<br />

100 M 0.01%<br />

1 G to 110 G 0.1%<br />

Capacitance Meter 0.33 nF to 3.3 nF<br />

3.4 nF to 330 nF<br />

331 nF to 1mF<br />

2%<br />

0.2%<br />

0.1%<br />

Standard Method/<br />

Reference<br />

Standard<br />

On-Site Calibration<br />

INSCMP 091, 065<br />

AC/DC Clampmeter 1 to 10 A 4% On-Site Calibration<br />

11 to 30 A 2% INSCMP 001, 002,<br />

31 to 40 A 1.5% 065<br />

41 to 220 A 1.0%<br />

221 to 500 A 0.5%<br />

501 to 1000 A 0.5%<br />

Insulation tester 0 to 10 G 0.1% On-Site Calibration<br />

Earth resistance<br />

0 to 100 M 0.1%<br />

INSCMP 007, 065<br />

On-Site Calibration<br />

tester<br />

INSCMP 070, 065<br />

Groundstrap tester 0 to 110 G 0.1% On-Site Calibration<br />

INSCMP 071, 065<br />

Surface resistance 0 to 110 G 0.1% On-Site Calibration<br />

tester<br />

INSCMP 083, 065<br />

Digital Multimeter<br />

(up to 6 ½ digit)<br />

@ DC voltage 0 to 50 mV 0.01% On-Site Calibration<br />

51 mV to 1000 V 0.001% INSCMP 018, 065<br />

@ AC voltage 0 to 100 mV 0.05% On-Site Calibration<br />

101 mV to 1000 V 0.007% INSCMP 018, 065<br />

@ DC current 0 to 1 mA 0.01% On-Site Calibration<br />

1.1 mA to 100 mA 0.006% INSCMP 018, 065<br />

101 mA to 2 A 0.01%<br />

3 A to 11 A 0.05%<br />

12 A to 50 A 0.1%<br />

@ AC current 0 to 1 mA 0.04% On-Site Calibration<br />

1.1 mA to 100 mA 0.02% INSCMP 018, 065<br />

101 mA to 11 A 0.06%<br />

12 A to 50 A 0.5%<br />

@ Resistance 0.1 m 0.6% On-Site Calibration<br />

1 m 0.06% INSCMP 018, 065<br />

10 m 0.06%<br />

100 m 0.006%<br />

1 0.0001%<br />

10 0.0015%<br />

100 0.0015%<br />

1 k 0.0002%<br />

10 k 0.001%<br />

100 k 0.001%<br />

1 M 0.002%<br />

10 M 0.004%<br />

100 M 0.01%<br />

Ultr<strong>as</strong>onic Flow<br />

Detector<br />

Electronic Load<br />

(voltage & current<br />

output only)<br />

1 G to 110 G 0.1%<br />

Horizontal linearity 0.01% scale<br />

division<br />

Vertical linearity 0.1% scale<br />

division<br />

0 to 100 V<br />

0.01%<br />

0 to 50 A<br />

0.1%<br />

On-Site Calibration<br />

INSCMP 026, 065<br />

On-Site Calibration<br />

INSCMP 026, 065<br />

On-Site Calibration<br />

INSCMP 077, 065

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!