Products/<br />

Cl<strong>as</strong>s <strong>of</strong> Test<br />

.01 Frequency<br />

characteristics<br />

Me<strong>as</strong>ured<br />

quantities/<br />

instrument<br />

Calibration <strong>of</strong><br />

Frequency<br />

characteristics<br />

Calibration <strong>of</strong> Input<br />

characteristics<br />

Calibration <strong>of</strong> Timing<br />

Characteristics<br />

Range to be<br />

calibrated<br />

279 <strong>of</strong> 391<br />

Best<br />

me<strong>as</strong>urement<br />

capability<br />

expressed <strong>as</strong> an<br />

uncertainty ()*<br />

Standard Method/<br />

Reference<br />

Standard<br />

0 to 250 MHz ± 1.16 % PMSI 200-014-00<br />

.02 Input<br />

characteristics<br />

0 to 100 V ± 1.16 % PMSI 200-014-00<br />

.03 Timing<br />

characteristics<br />

5.42 High voltage equipment<br />

1 nsec. to 5 sec. ± 0.25 % PMSI 200-014-00<br />

.01 Direct voltage Calibration <strong>of</strong> High<br />

0 to 5 kV ± 0.8 % PMSI 200-034-00<br />

tests<br />

Voltage DC<br />

.02 Alternating Calibration <strong>of</strong> High<br />

0 to 5 kV<br />

± 0.8 % PMSI 200-034-00<br />

voltage tests Voltage AC<br />

@ 60 Hz<br />

5.44 Calibration <strong>of</strong> Temperature Me<strong>as</strong>urement Equipment<br />

.13 Digital<br />

Calibration <strong>of</strong> Digital 0 to 100 °C ± 0.57 °C PMSI 200-081-00<br />

Temperature Temperature<br />

Indicator<br />

Systems<br />

Indicator Systems<br />

5.45 Calibration <strong>of</strong> Ancillary Temperature Me<strong>as</strong>uring Instruments<br />

.04 Indicators, Calibration <strong>of</strong> - 200 to 1370 °C 0.42°C With on-site<br />

Recorders and Temperature<br />

calibration<br />

Controllers<br />

5.48 Hygrometry<br />

Indicators,<br />

Controllers and<br />

Recorders<br />

PMSI 200-118-00<br />

.01 Calibration <strong>of</strong> Calibration <strong>of</strong> Temperature<br />

± 0.4 °C PMSI 200-004-00<br />

Humidity Humidity Me<strong>as</strong>uring @ 19 to 23 °C<br />

Me<strong>as</strong>uring Devices<br />

Humidity<br />

± 2.1% R.H.<br />

Devices<br />

@ 30 to 50 %R.H.<br />

* A reported uncertainty will be that for the instrument itself during calibration plus the appropriate<br />

me<strong>as</strong>urement capability <strong>of</strong> the laboratory. The uncertainties are b<strong>as</strong>ed on an estimated confidence<br />

probability <strong>of</strong> approximate 95% unless otherwise stated.