Instructions for use: Ikus - Berlin Heart
Instructions for use: Ikus - Berlin Heart
Instructions for use: Ikus - Berlin Heart
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Messages<br />
The error is only detected by the active (or passive)<br />
controller 69<br />
Mobilization of patient 59<br />
Monitoring<br />
Blood values 55<br />
Monitoring procedure 51<br />
Monitoring program 13, 16<br />
Adjust the parameter values 23<br />
Drive off 25<br />
Drive pa<strong>use</strong> 25<br />
Fundamentals 21<br />
Logging <strong>use</strong>rs on and off 21<br />
Message window 22, 24<br />
Parameter table 22<br />
Pa<strong>use</strong> left/Pa<strong>use</strong> right 25<br />
Pressure graph 22<br />
Pump size and single-step mode 35<br />
Select options 23<br />
Moving<br />
the <strong>Ikus</strong> 29<br />
Multiorgan failure 5<br />
N<br />
Nuclear diagnostics 4<br />
Nuclear therapy 4<br />
Numlock 19<br />
Marking of status LED 90<br />
Nurse call (external alarm) 4, 14<br />
O<br />
Objectives of the therapy 5<br />
Obturator 44<br />
Operating mode 16<br />
Asynchronous mode 16, 37<br />
biventricular 16<br />
Separate pulse 16, 38<br />
Synchronous mode 16, 37<br />
univentricular 16<br />
Operation, after the 52<br />
Operator obligations 6<br />
P<br />
Packaging 6, 29<br />
Packing<br />
the <strong>Ikus</strong> 30<br />
Parameter<br />
Startup parameters 35<br />
table 22<br />
Target values <strong>for</strong> normal operation, recommended<br />
38<br />
Test parameters 33<br />
Platelet aggregation inhibition therapy<br />
Adolescents, adults 56<br />
EXCOR Pediatric 56<br />
Potential equalization 14<br />
Power supply 15<br />
INDEX<br />
Battery mode 15<br />
Mains power 15<br />
red LED 15<br />
Switching between mains power and battery mode<br />
26<br />
yellow LEDs 15<br />
Power switch (mains power switch) 14<br />
Pressure error 67<br />
Pressure gauge 88<br />
Pressure gauge set 43, 88<br />
Pressure graph 22<br />
Pressure vessel 32<br />
Product range 85<br />
Pump log 94<br />
Pump size and single-step mode 35<br />
Pump: see blood pump<br />
R<br />
Radiotherapy 4<br />
Replace the<br />
blood pump 75<br />
driving tube 65<br />
Replacing the blood pump<br />
, standard <strong>for</strong>m 98<br />
Risks and adverse effects 4<br />
Routine start test: see start test<br />
1000002 Rev. 4.9.1 xi<br />
S<br />
Self-test of the alarm circuit 21<br />
Separate pulse 16, 38<br />
Sepsis 5<br />
Signs of infection 5<br />
Single-step mode 36<br />
Special range 88<br />
Standard <strong>for</strong>m<br />
EXCOR emergency log 96<br />
EXCOR implantation record 91<br />
EXCOR parameter log 95<br />
EXCOR pump log 94<br />
Standard <strong>for</strong>m: Replacing the blood pump 98<br />
standard values, default 81<br />
Start test<br />
after emergency pulse mode 79<br />
Error messages 73<br />
Routine test<br />
Start the<br />
blood pump 36<br />
Starting the<br />
monitoring program 21<br />
Startup parameters 35<br />
Sterility 6, 41<br />
Stop the<br />
blood pump 24<br />
Storage 6<br />
Suction pressure 37<br />
Synchronous mode 16, 37<br />
System accessories 88