10.07.2015 Views

Architecture and management of a geological repository - Andra

Architecture and management of a geological repository - Andra

Architecture and management of a geological repository - Andra

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

6 – Overall underground architecture6.6.5 Sensitivity <strong>of</strong> the footprint <strong>of</strong> the <strong>repository</strong> to the pre-disposal storage duration.The footprint <strong>of</strong> the B waste <strong>and</strong> C0 waste <strong>repository</strong> zones does not depend on the pre-disposalstorage duration. For highly exothermal packages, the total footprint <strong>of</strong> the <strong>repository</strong> zones resultsfrom that <strong>of</strong> the <strong>repository</strong> modules, sensitive to the pre-disposal storage duration, <strong>and</strong> the distancesbetween these modules. The C waste <strong>repository</strong> zone for the scenario S1a has an footprint <strong>of</strong>approximately 500 hectares for a previous surface storage from 60 years (for the reference packagesC1/C2) to 70 years (for the reference packages C3/C4). Above a certain storage duration, thesensitivity <strong>of</strong> this footprint is attenuated: it becomes 300 hectares for a surface storage duration <strong>of</strong>150 years (Figure 6.6.5) <strong>and</strong> is reduced by half for a duration <strong>of</strong> 200 years. Under the assumption <strong>of</strong> a<strong>repository</strong> with spent fuels (scenario S2), a similar sensitivity is observed for the footprint to the predisposalsurface storage duration (Figure 6.6.6). This sensitivity varies with the speeds <strong>of</strong> thermaldecrease <strong>of</strong> the different types <strong>of</strong> packages.B zone100 haB zone100 haC0 zone 8 haC0 zone 8 haC zone500 haC zone300 haPre-disposal storage duration60 years for C1 <strong>and</strong> C2 wastes70 years for C3 <strong>and</strong> C4 wastesPre-disposal storage duration150 years for C wastesScenario S1aFigure 6.6.5Sensitivity <strong>of</strong> the footprint <strong>of</strong> a <strong>repository</strong> to the previous surface storageduration <strong>of</strong> highly exothermal packages - scenario S1aDOSSIER 2005 ARGILE -ARCHITECTURE AND MANAGEMENT OF A GEOLOGICAL DISPOSAL SYSTEM286/495

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!