10.07.2015 Views

Architecture and management of a geological repository - Andra

Architecture and management of a geological repository - Andra

Architecture and management of a geological repository - Andra

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

11 – Operational SafetyTemperatureThe diagram [downstream distance from the fire (m) / time since outbreak <strong>of</strong> fire (s) / temperature(°C)] highlights the influence <strong>of</strong> the smoke clearance system 171 the operation <strong>of</strong> which deflects the risein temperature <strong>of</strong> the air in the drifts downstream <strong>of</strong> the fire ventilation airflow.The simulation (see Figure 11.4.6) shows that the evacuation <strong>of</strong> personnel located downstream <strong>of</strong> thefire should be possible under acceptable conditions even for personnel close to the seat <strong>of</strong> the fire.Personnel escaping at normal speed reach the interconnecting drift in an atmosphere at a airtemperature <strong>of</strong> below 30°C, <strong>and</strong> between 40°C <strong>and</strong> 50°C if they are slowed down by the presence <strong>of</strong> acasualty. These conditions remain acceptable with respect to the 80°C threshold mentioned previously.Arrival atinterconnectingdriftSmokeclearancesystem startsEvacuationat 0.5 m/sEvacuationat 1 m/sFireFigure 11.4.6Spatio-temporal evolution <strong>of</strong> the air temperature (°C) in the case <strong>of</strong> a fire in atype C waste cell access drift during nuclear operation – Representation <strong>of</strong> themovement <strong>of</strong> personnel located downstream the fore ventilation airflowCarbon monoxide concentrationUsing the same approach as before, the simulation shows that persons located downstream <strong>of</strong> the fireventilation, escaping at normal speed, can reach the interconnecting drift under healthy conditions. Atan evacuation speed reduced to 0.5 m/s, personnel arrive at the interconnecting drift in an atmospherewhose a carbon monoxide content (pf around 200 ppm) is still below the 500 ppm threshold.OpacityThe simulation shows that personnel escaping at 1 m/s can reach the interconnecting drift withoutbeing hindered by the opacity, which remains under 0.10 m -1 , corresponding to a visibility <strong>of</strong> around10 metres.171 It was considered that that the smoke clearance installations would be started up 5 minutes (300 seconds) after the outbreak <strong>of</strong> the fire<strong>and</strong> that a stable state would be established after 8 minutes. These data come from experiments in underground structuresDOSSIER 2005 ARGILE -ARCHITECTURE AND MANAGEMENT OF A GEOLOGICAL DISPOSAL SYSTEM462/495

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!