10.07.2015 Views

work plan for soil remediation, sampling and analysis plan, site ...

work plan for soil remediation, sampling and analysis plan, site ...

work plan for soil remediation, sampling and analysis plan, site ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

. . . --..7.0 AIR MONITORINGAir monitoring will be conducted in order to determine airborne contamination levels. Thisensures that respiratory protection is adequate to protect personnel against the chemicals thatare encountered. The following air monitoring ef<strong>for</strong>ts will be used at this <strong>site</strong>. Additional airmonitoring may be conducted at the discretion of the SSO.The followingchart describes the air monitoring required <strong>and</strong> appropriate action levels.MonitoringDeviceLEL& (<strong>work</strong> area)To be per<strong>for</strong>med during <strong>soil</strong>excavation <strong>and</strong> direct loadoutoperationsActionLevel>lO% LEL500 ppm <strong>for</strong> 5 min.Level C, monitor with benzenedragertubesStop operations <strong>and</strong> allow vapors todissipate to less than 500 ppmbe<strong>for</strong>e continuingBenzene Dmger Tubes >0.5 ppm Upgrade to Level CWhen PID readings are >lO ppm in >25 ppm Stop operations <strong>and</strong> allow vapors toBreathing Zonedissipate prior to continuingMini-Ram (Breathing Zone) >2.5 mg/m3 <strong>for</strong> 5 min. Level CI’o be per<strong>for</strong>med during <strong>soil</strong> >5.0 mg/m3 <strong>for</strong> 5 min Stop operations <strong>and</strong> institute dustexcavation <strong>and</strong> direct loadoutcontml measuresoperations7.1 LOWER EXPLOSIVE LIMIT/OXYGEN (LEL/02) METERPrior to entering a confined-space area or per<strong>for</strong>ming hot <strong>work</strong> involving welding, cutting, orother high heat-producing operations where flammable or combustible vapors may be present,LEL/O2 measurements will be taken.7.2 PHOTOIONIZATION DETECTOR (PID)A PID will be used to monitor total ionizable organic content of the ambient air. A PID willprove useful as a direct reading instrument to aid in determining if respiratory protection needsto be upgraded <strong>and</strong> to define the EZ. Although organic compounds are not anticipated to beOHM Project 16487SSHSP Health <strong>and</strong> Srfay Plan July 1995In<strong>for</strong>mation herein is proprietary <strong>and</strong> confidential <strong>and</strong> to be used ot rdeased to othen only with explicit wriy permission of OHM Rantdiationselvices Corp.7-l

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!