LBi-6: High Frequency Lighting<br />

Intent To promote indoor visual comfort through the use of high frequency lighting solutions.<br />

Credit<br />

Requirements<br />

Awarding<br />

Credit Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

Calculations<br />

and<br />

Methodology<br />

GENERAL<br />

No incandescent lamps may be installed in the internal environment, and all internal and<br />

permanently installed fluorescent lighting installations must incorporate high frequency<br />

electronic ballasts. For projects with no control over fit-out of lighting installations,<br />

provide contractual extracts from the tenant lease highlighting how this credit will be<br />

met.<br />

Install occupancy sensors in all rooms intended for individual occupancy, conferencing or<br />

meeting rooms, open plan offices spaces and hallways or corrirdors.<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

Residential<br />

No incandescent lamps may be installed in the internal environment, and 95% of all<br />

permanently installed internal lighting installations (by number of fittings) must<br />

incorporate high frequency electronic ballasts.<br />

Install occupancy sensors in all communal spaces of the building including hallways.<br />

CREDIT POINTS REQUIREMENTS<br />

1<br />

(maximum)<br />

1<br />

1<br />

(maximum)<br />

1<br />

Design <strong>Rating</strong><br />

General: All high frequency fluorescent ballasts and occupancy<br />

sensors meeting credit requirements.<br />

Residential: 95% high frequency fluorescent ballasts and<br />

communal area occupancy sensors meeting credit requirements.<br />

Construction <strong>Rating</strong><br />

General: All high frequency fluorescent ballasts and occupancy<br />

sensors meeting credit requirements.<br />

Residential: 95% high frequency fluorescent ballasts and<br />

communal area occupancy sensors meeting credit requirements.<br />

� Confirmation that no incandescent lamps are to be installed.<br />

� Extracts from specifications indicating requirements for high frequency electronic<br />

ballasts and occupancy sensors; or<br />

� Comprehensive luminaire schedule including ballast specifications.<br />

� Confirmation that all spaces comply with the requirements for occupancy sensors<br />

� Confirmation that no incandescent lamps are installed.<br />

� Purchase receipts and associated technical data sheets for all lighting system<br />

installations and occupancy sensors associated with all occupied spaces; and<br />

� Representative photographs of lighting installations.<br />

None<br />

References None<br />

<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 104 of 223