Calculations<br />

and<br />

Methodology<br />

References None<br />

Calculation of Daylight Illuminance<br />

Daylighting design software must be<br />

used to calculate internal daylight<br />

illuminance. Software calculation<br />

control parameters must be based on<br />

the higher settings recommended for<br />

calculation of values rather than lower<br />

settings required for visualization<br />

purposes. One such control setting,<br />

the number of inter-reflections which<br />

equates to the number of bounces of<br />

diffuse reflected indirect light, must<br />

be set to a minimum of 7. Courtesy of Hilson Moran<br />

The daylight illuminance in Lux must be calculated based on a CIE standard clear sky at<br />

10am, 12pm and 2pm on the equinox and summer solstice excluding contributions from<br />

any artificial lighting. The report submitted must identify the key parameters used in the<br />

simulation, especially with regard to glazing visible light transmittance and the<br />

reflectance of all internal surfaces.<br />

Offices and Schools<br />

No glazed area below 762mm height from finished floor level can be included in the<br />

simulations.<br />