SM-2: Design for Materials Reduction<br />

Intent To reduce the overall amount of material used in the development of buildings.<br />

Credit<br />

Requirements<br />

Awarding Credit<br />

Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

Calculations and<br />

Methodology<br />

References None<br />

GENERAL<br />

Demonstrate that fewer materials are used in the final building design than in a typical<br />

building of the same type by achieving at least one of the following initiatives:<br />

� At least 90% of the interior floor area does not include finishes (apart from<br />

sealant);<br />

� At least 90% of the ceiling area does not have any ceiling systems (exposed ceilings<br />

only); or<br />

� Use of dual function surfaces or materials such as:<br />

o <strong>Building</strong> Integrated Photovoltaics (BIPV) replacing traditional building<br />

envelope materials on at least 10% of the area of the building envelope<br />

(including roof);<br />

o Vegetated roofs on at least 50% of the area of roof. (Plant selection should<br />

favor native and drought-resistant species. This section of the roof must<br />

also be accessible to building users); or<br />

o Vegetated walls on at least 10% of the area of all interior partitions (Plant<br />

selection should favor native and drought-resistant species).<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

Office<br />

Office buildings must achieve at least two of three initiatives from the list above.<br />

CREDIT POINTS REQUIREMENTS<br />

1<br />

(maximum)<br />

1<br />

1<br />

(maximum)<br />

1<br />

Design <strong>Rating</strong><br />

General: <strong>Building</strong> is designed with at least one material<br />

reduction initiative.<br />

Offices only: At least two initiatives are required.<br />

Construction <strong>Rating</strong><br />

General: <strong>Building</strong> is constructed with at least one material<br />

reduction initiative.<br />

Offices only: At least two initiatives are required.<br />

� Brief narrative describing how the project intends to meet the Credit<br />

Requirements, including any calculations; and<br />

� Extracts from specifications requiring the proposed initiative(s).<br />

� Updated brief narrative describing how the project intends to meet the Credit<br />

Requirements, including any calculations; and<br />

� Calculations and photographs of the relevant features confirming the initiatives<br />

meet credit requirements.<br />

Area calculations are required and must show a comparison between a traditional<br />

approach and current design using reduced amount of materials.<br />