SM-1: Non-Polluting Materials<br />

Intent To promote the selection of materials that do not have long-term negative impacts on<br />

human health or pollute natural systems.<br />

Credit<br />

Requirements<br />

GENERAL<br />

Demonstrate that the project has achieved the following:<br />

Zero ODP, Low GWP Insulation<br />

� 1 Credit Point: All thermal insulation materials used in the project have an Ozone<br />

Depleting Potential of zero (ODP = 0) and a low Global Warming Potential of less<br />

than five (GWP �5). Compliance is required for any blowing agent used to<br />

manufacture the insulation product or to spray it in place.<br />

Chlorine Free Materials<br />

� 1 Credit Point: Replace ‘business as usual’ use of chlorine-based materials<br />

including Polyvinyl Chloride (PVC), Chlorinated polyethylene (CPE), Chlorinated<br />

polyvinyl chloride (CPVC), Chlorosulfonated polyethylene (CSPE), and<br />

Polychloroprene with more sustainable alternatives for three or more of the<br />

following building product groups (The proportions required are indicated below):<br />

o Insulation (80% or more by surface area);<br />

o Waterproofing sheets and membranes (50% or more by surface area);<br />

o External cladding (90% or more by surface area);<br />

o Floor and wall coverings (90% or more by surface area);<br />

o Windows and door frames (90% or more by linear length);<br />

o Pipes (50% or more by linear length); and<br />

o Electrical Cables, cable sheathing and Conduits (50% or more by linear<br />

length).<br />

Low Toxicity Materials<br />

� 1 Credit Point: Eliminate materials or building products or components<br />

containing elements or compounds with the following R-phrase attribution under<br />

EU Risk Phrases (R-Phrases) listed in Annex III of EU Directives 67/548/EEC:<br />

o R20 - Harmful by inhalation.<br />

o R21 - Harmful in contact with skin.<br />

o R22 - Harmful if swallowed.<br />

o R23 - Toxic by inhalation.<br />

o R24 - Toxic in contact with skin.<br />

o R25 - Toxic if swallowed.<br />

o R26 - Very toxic by inhalation.<br />

o R27 - Very toxic in contact with skin.<br />

o R28 - Very toxic if swallowed.<br />

o R29 - Contact with water liberates toxic gas.<br />

o R31 - Contact with acids liberates toxic gas.<br />

o R32 - Contact with acids liberates very toxic gas.<br />

o R33 - Danger of cumulative effects.<br />

o R36 - Irritating to eyes.<br />

o R37 - Irritating to respiratory system.<br />

o R38 - Irritating to skin.<br />

o R39 - Danger of very serious irreversible effects.<br />

o R41 - Risk of serious damage to eyes.<br />

o R42 - May cause sensitization by inhalation.<br />

o R43 - May cause sensitization by skin contact.<br />

o R45 - May cause cancer.<br />