SM-3: Design for Flexibility & Adaptability<br />

Intent To lengthen the useful life of buildings through designs that are easily adaptable for<br />

other program uses.<br />

Credit<br />

Requirements<br />

Awarding Credit<br />

Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

Calculations and<br />

Methodology<br />

GENERAL<br />

Demonstrate the following:<br />

� 90% of the building has regular rhythm to exposed facades (by area);<br />

� Floor-to-floor heights of at least 3.6 meters;<br />

� 90% of the windows are evenly distributed around exposed elevations (by area);<br />

� 90% of interior, non-structural walls are demountable or movable (by area); and<br />

� 90% of pipes, wiring and conduits are not permanently embedded in building<br />

materials (in length).<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

None<br />

CREDIT POINTS REQUIREMENTS<br />

1<br />

(maximum)<br />

1<br />

1<br />

(maximum)<br />

1<br />

Design <strong>Rating</strong><br />

<strong>Building</strong> is designed to meet Credit Requirements for flexibility<br />

and adaptability.<br />

Construction <strong>Rating</strong><br />

<strong>Building</strong> is constructed to meet Credit Requirements for<br />

flexibility and adaptability.<br />

� Brief narrative describing how the project intends to meet the Credit<br />

Requirements, including any calculations;<br />

� <strong>Building</strong> elevations clearly indicating how the building has regular rhythm to<br />

exposed facades, floor-to-floor heights and distribution of windows;<br />

� Typical floor plan indicating the location of any load bearing walls and other<br />

interior walls as well as any connections for movable/demountable walls; and<br />

� Drawings indicating plumbing and electrical services are not to be permanently<br />

embedded in building materials.<br />

� Updated narrative describing how the project intends to meet the Credit<br />

Requirements, including any calculations;<br />

� Photographs clearly illustrating how the building has regular rhythm to exposed<br />

facade, floor-to-floor heights and distribution of windows;<br />

� Photographs of movable/demountable walls; and<br />

� As Built drawings illustrating how plumbing and electrical services have not been<br />

permanently embedded in building materials.<br />