RE-4: Vertical Transportation<br />

Intent To promote projects that specify and install energy efficient vertical movement and<br />

transportation systems<br />

Credit<br />

Requirements<br />

GENERAL<br />

Easily Accessible Stairs<br />

� 1 Credit Point: Demonstrate that there are easily accessible stairs to at least the first<br />

three floors (or to all floors if the building is less than three stories), and that the<br />

stairs are either visible from the main entrance or visible from the main building lifts.<br />

The stairs must have the following characteristics:<br />

� Achieve a minimum lighting level of 150 lux measured at the walking surfaces;<br />

� Open or visible on at least one side; and<br />

� All artificial lighting used within the stairs must be supplied with colour corrected<br />

lamps which provide a minimum Color Rendering Index (CRI) of 80.<br />

Energy Efficient Lifts<br />

� 1 Credit Point: Demonstrate that all lifts within the building are energy efficient as<br />

follows:<br />

� Offer ‘idle/downtime’ features allowing the lift to operate in a stand-by mode<br />

during off-peak periods;<br />

� Include a regenerative drive system (buildings over three stories only); and<br />

� Use LED lighting and LCD display features.<br />

Energy Efficient Escalators/Travelators<br />

� 1 Credit Point: Demonstrate that all escalators and travelators within the building are<br />

energy efficient as follows:<br />

� Offer an automated stop/start function linked to occupancy sensors to enable<br />

standby mode when there is no passenger demand; and<br />

� Use LED strip lighting.<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

� Simple platform/wheelchair lifts and electronic ramps are not subject to the<br />

requirements of this credit.<br />