SM-7: <strong>Building</strong> Reuse<br />

Intent To encourage the reuse and improvement of existing building stock, reduce waste and<br />

other environmental impacts associated with new materials extraction, manufacturing,<br />

and transport.<br />

Credit<br />

Requirements<br />

Awarding Credit<br />

Points<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

Credit<br />

Submission:<br />

Construction<br />

<strong>Rating</strong><br />

Calculations and<br />

Methodology<br />

GENERAL<br />

References None<br />

Demonstrate that a portion of the building structural system, by surface area, is reused<br />

from an existing building. as follows:<br />

� 1 Credit Point: At least 25% of the building structural system, by surface area, will<br />

be reused.<br />

� 2 Credit Points: At least 50% of the building structural system, by surface area, will<br />

be reused.<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

None<br />

CREDIT POINTS REQUIREMENTS<br />

2<br />

(maximum)<br />

1<br />

2<br />

2<br />

(maximum)<br />

1<br />

2<br />

Design <strong>Rating</strong><br />

At least 25% of the building structural system, by surface area,<br />

will be reused.<br />

At least 50% of the building structural system, by surface area,<br />

will be reused.<br />

Construction <strong>Rating</strong><br />

At least 25% of the building structural system, by surface area, is<br />

reused.<br />

At least 50% of the building structural system, by surface area, is<br />

reused.<br />

� Narrative describing how the project intends to meet the Credit Requirements,<br />

including calculations demonstrating the amount of surface area to be reused; and<br />

� Plan drawings of the proposed building and demolition plan of the existing building<br />

demonstrating the amount of surface area to be reused.<br />

� Updated narrative describing how the project meets the Credit Requirements,<br />

including calculations demonstrating the amount of surface area to be reused;<br />

� As-built drawings of the new building and demolition drawings of the existing<br />

building demonstrating the amount of surface area reused; and<br />

� Site photographs illustrating the reuse of the existing structural system.<br />

<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 184 of 223