Pearl Building Rating System - Estidama
Pearl Building Rating System - Estidama
Pearl Building Rating System - Estidama
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Awarding Credit<br />
Points<br />
Credit<br />
Submission:<br />
Design <strong>Rating</strong><br />
Credit<br />
Submission:<br />
Construction<br />
<strong>Rating</strong><br />
CREDIT POINTS<br />
REQUIREMENTS<br />
3<br />
Design <strong>Rating</strong><br />
(maximum)<br />
Demonstrate that easily accessible stairs shall be provided to at<br />
1<br />
least the first three floors of the building.<br />
Demonstrate that all lifts within the building shall be energy<br />
1<br />
efficient.<br />
Demonstrate that all escalators/ travelators within the building<br />
1<br />
shall be energy efficient.<br />
3<br />
Construction <strong>Rating</strong><br />
(maximum)<br />
Demonstrate that easily accessible stairs have been provided to at<br />
1<br />
least the first three floors of the building.<br />
1 Demonstrate that all lifts within the building are energy efficient.<br />
Demonstrate that all escalators/travelators within the building are<br />
1<br />
energy efficient.<br />
Easily Accessible Stairs<br />
� Brief narrative indicating how the project will meet the credit requirements;<br />
� Plan and elevation drawings detailing the staircase design and their location(s)<br />
within the building;<br />
� Lighting calculations demonstrating that the minimum lux levels will be achieved<br />
on the stairs measured at the walking surfaces at any time; and<br />
� Extracts from lighting specifications confirming that all light fittings within the<br />
stairs achieve the minimum color rendering index required.<br />
Energy Efficient Lifts<br />
� Brief narrative indicating how the project will meet the credit requirements; and<br />
� Extracts from the lift specifications detailing the ‘idle/downtime’ features,<br />
regenerative drive system and confirmation that specified lighting is LED and any<br />
display features are LCD.<br />
Energy Efficient Escalators and Travelators<br />
� Brief narrative indicating how the project will meet the credit requirements; and<br />
� Extracts from the escalator/travelator specifications detailing the automated<br />
stop/start system, occupancy sensors and confirmation that specified strip lighting<br />
is LED.<br />
Easily Accessible Stairs<br />
� Updated narrative including photographic evidence indicating how the project<br />
meets the credit requirements;<br />
� As-built plan and elevation drawings detailing the staircase design and their<br />
location(s) within the building;<br />
� Lighting measurements demonstrating that a minimum of 150 lux is achieved at the<br />
walking surfaces at any time; and<br />
� Manufacturer’s information confirming that all light fittings within the stairs<br />
achieve the minimum color rendering index required.<br />
Energy Efficient Lifts<br />
� Updated narrative including photographic evidence indicating how the project<br />
meets the credit requirements; and<br />
� Manufacturer’s information of the installed lift(s) detailing the ‘idle/downtime’<br />
features, regenerative drive system and confirmation that installed lighting is LED<br />
<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 159 of 223