12.01.2013 Views

Pearl Building Rating System - Estidama

Pearl Building Rating System - Estidama

Pearl Building Rating System - Estidama

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

LBo-R3: Outdoor Thermal Comfort Strategy<br />

Intent To increase outdoor thermal comfort during transition months and reduce thermal<br />

discomfort during summer months in public spaces and walkways.<br />

Credit<br />

Requirements<br />

Requirement<br />

Achievement<br />

Credit<br />

Submission:<br />

Design <strong>Rating</strong><br />

GENERAL<br />

Demonstrate that an outdoor thermal comfort strategy has been employed to improve<br />

the building’s exterior microclimate. The strategy is to consider the following as<br />

appropriate within the project’s specific context:<br />

� Orientation;<br />

� Shading;<br />

� Selection of high-albedo surfaces;<br />

� Ventilation;<br />

� Evaporative cooling;<br />

� Radiative cooling; and<br />

� Thermal mass.<br />

Shade measures (cover or shade) must be provided in all applicable spaces and achieve<br />

the following minimum % shading:<br />

Space Type Minimum % shading<br />

Exterior Surface Parking with more than 10 spaces<br />

(including parking on roof surfaces)<br />

40%<br />

Public Open Spaces (including privately owned) 60%<br />

Primary Pedestrian Walkways (based on 1.8m width<br />

within the through zone)<br />

Secondary Pedestrian Walkways (based on 1.8m width<br />

within the through zone)<br />

<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 55 of 223<br />

75%<br />

75%<br />

Cycle Tracks 50%<br />

Playgrounds 90%<br />

ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />

� Where cover is provided by structures such as canopies or other architectural<br />

elements, the outer surface of the shading element must have a minimum Solar<br />

Reflectance Index (SRI) of 29.<br />

� Shade from trees is to be measured at 3 years growth.<br />

� Public realm spaces shade requirements excludes active recreational areas such as<br />

playing fields and ball courts.<br />

This is a requirement. There are no Credit Points awarded.<br />

� Outdoor Thermal Comfort Strategy report highlighting all measures contributing to<br />

improving the building’s exterior microclimate including:<br />

� narrative;<br />

� drawings of the public realm spaces and priority shade areas;<br />

� Plan and tabulated results showing achievement of % of shading of applicable<br />

spaces at 1:00pm clock time on the Equinox and Summer Solstice; and<br />

� Extracts from specifications relating to the SRI of all cover elements.