LBo-R3: Outdoor Thermal Comfort Strategy<br />
Intent To increase outdoor thermal comfort during transition months and reduce thermal<br />
discomfort during summer months in public spaces and walkways.<br />
Credit<br />
Requirements<br />
Requirement<br />
Achievement<br />
Credit<br />
Submission:<br />
Design <strong>Rating</strong><br />
GENERAL<br />
Demonstrate that an outdoor thermal comfort strategy has been employed to improve<br />
the building’s exterior microclimate. The strategy is to consider the following as<br />
appropriate within the project’s specific context:<br />
� Orientation;<br />
� Shading;<br />
� Selection of high-albedo surfaces;<br />
� Ventilation;<br />
� Evaporative cooling;<br />
� Radiative cooling; and<br />
� Thermal mass.<br />
Shade measures (cover or shade) must be provided in all applicable spaces and achieve<br />
the following minimum % shading:<br />
Space Type Minimum % shading<br />
Exterior Surface Parking with more than 10 spaces<br />
(including parking on roof surfaces)<br />
40%<br />
Public Open Spaces (including privately owned) 60%<br />
Primary Pedestrian Walkways (based on 1.8m width<br />
within the through zone)<br />
Secondary Pedestrian Walkways (based on 1.8m width<br />
within the through zone)<br />
<strong>Pearl</strong> <strong>Building</strong> <strong>Rating</strong> <strong>System</strong>: Design & Construction, Version 1.0, April 2010 55 of 223<br />
75%<br />
75%<br />
Cycle Tracks 50%<br />
Playgrounds 90%<br />
ADDITIONAL REQUIREMENT/CLARIFICATIONS<br />
� Where cover is provided by structures such as canopies or other architectural<br />
elements, the outer surface of the shading element must have a minimum Solar<br />
Reflectance Index (SRI) of 29.<br />
� Shade from trees is to be measured at 3 years growth.<br />
� Public realm spaces shade requirements excludes active recreational areas such as<br />
playing fields and ball courts.<br />
This is a requirement. There are no Credit Points awarded.<br />
� Outdoor Thermal Comfort Strategy report highlighting all measures contributing to<br />
improving the building’s exterior microclimate including:<br />
� narrative;<br />
� drawings of the public realm spaces and priority shade areas;<br />
� Plan and tabulated results showing achievement of % of shading of applicable<br />
spaces at 1:00pm clock time on the Equinox and Summer Solstice; and<br />
� Extracts from specifications relating to the SRI of all cover elements.